{"product_id":"banner-im-t-9a-safety-relay-module","title":"Banner IM-T-9A","description":"\u003ch2 data-start=\"403\" data-end=\"448\"\u003e\u003cstrong data-start=\"406\" data-end=\"446\"\u003eBanner IM-T-9A\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"450\" data-end=\"468\"\u003e\u003cstrong data-start=\"454\" data-end=\"466\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"469\" data-end=\"828\"\u003eThe \u003cstrong data-start=\"473\" data-end=\"491\"\u003eBanner IM-T-9A\u003c\/strong\u003e is a \u003cstrong data-start=\"497\" data-end=\"520\"\u003esafety relay module\u003c\/strong\u003e engineered for monitoring emergency stop buttons, safety gates, and light curtains in industrial automation systems. It features \u003cstrong data-start=\"650\" data-end=\"679\"\u003etwo-channel safety inputs\u003c\/strong\u003e, \u003cstrong data-start=\"681\" data-end=\"708\"\u003e24 V DC control voltage\u003c\/strong\u003e, and \u003cstrong data-start=\"714\" data-end=\"742\"\u003eredundant safety outputs\u003c\/strong\u003e, ensuring dependable safety performance in compliance with international standards.\u003c\/p\u003e\n\u003ch3 data-start=\"830\" data-end=\"852\"\u003e\u003cstrong data-start=\"834\" data-end=\"850\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"853\" data-end=\"1216\"\u003e\n\u003cli data-start=\"853\" data-end=\"918\"\u003e\n\u003cp data-start=\"855\" data-end=\"918\"\u003eDual-channel safety inputs for redundancy and fault detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"919\" data-end=\"971\"\u003e\n\u003cp data-start=\"921\" data-end=\"971\"\u003eMonitors E-stops, interlocks, and safety devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"972\" data-end=\"1009\"\u003e\n\u003cp data-start=\"974\" data-end=\"1009\"\u003e24 V DC control voltage operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1010\" data-end=\"1067\"\u003e\n\u003cp data-start=\"1012\" data-end=\"1067\"\u003eTwo safety output relays for machine shutdown control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1068\" data-end=\"1106\"\u003e\n\u003cp data-start=\"1070\" data-end=\"1106\"\u003eCompact DIN-rail mountable housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1107\" data-end=\"1158\"\u003e\n\u003cp data-start=\"1109\" data-end=\"1158\"\u003eLED indicators for power and status diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1159\" data-end=\"1216\"\u003e\n\u003cp data-start=\"1161\" data-end=\"1216\"\u003eConforms to ISO 13849-1 and EN 954-1 safety standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1218\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1222\" data-end=\"1250\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1253\" data-end=\"1773\"\u003e\n\u003cli data-start=\"1253\" data-end=\"1275\"\u003e\n\u003cp data-start=\"1255\" data-end=\"1275\"\u003e\u003cstrong data-start=\"1255\" data-end=\"1265\"\u003eModel:\u003c\/strong\u003e IM-T-9A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1276\" data-end=\"1309\"\u003e\n\u003cp data-start=\"1278\" data-end=\"1309\"\u003e\u003cstrong data-start=\"1278\" data-end=\"1287\"\u003eType:\u003c\/strong\u003e Safety Relay Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1310\" data-end=\"1361\"\u003e\n\u003cp data-start=\"1312\" data-end=\"1361\"\u003e\u003cstrong data-start=\"1312\" data-end=\"1331\"\u003eInput Channels:\u003c\/strong\u003e 2 (dual-channel monitoring)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1362\" data-end=\"1394\"\u003e\n\u003cp data-start=\"1364\" data-end=\"1394\"\u003e\u003cstrong data-start=\"1364\" data-end=\"1384\"\u003eControl Voltage:\u003c\/strong\u003e 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1395\" data-end=\"1449\"\u003e\n\u003cp data-start=\"1397\" data-end=\"1449\"\u003e\u003cstrong data-start=\"1397\" data-end=\"1416\"\u003eSafety Outputs:\u003c\/strong\u003e 2 NO safety relays (redundant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1450\" data-end=\"1504\"\u003e\n\u003cp data-start=\"1452\" data-end=\"1504\"\u003e\u003cstrong data-start=\"1452\" data-end=\"1473\"\u003eAuxiliary Output:\u003c\/strong\u003e 1 NC or 1 NO (status output)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1505\" data-end=\"1535\"\u003e\n\u003cp data-start=\"1507\" data-end=\"1535\"\u003e\u003cstrong data-start=\"1507\" data-end=\"1525\"\u003eResponse Time:\u003c\/strong\u003e ≤ 25 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1536\" data-end=\"1585\"\u003e\n\u003cp data-start=\"1538\" data-end=\"1585\"\u003e\u003cstrong data-start=\"1538\" data-end=\"1557\"\u003eContact Rating:\u003c\/strong\u003e 6 A at 250 V AC \/ 30 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1586\" data-end=\"1612\"\u003e\n\u003cp data-start=\"1588\" data-end=\"1612\"\u003e\u003cstrong data-start=\"1588\" data-end=\"1601\"\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1613\" data-end=\"1652\"\u003e\n\u003cp data-start=\"1615\" data-end=\"1652\"\u003e\u003cstrong data-start=\"1615\" data-end=\"1636\"\u003eHousing Material:\u003c\/strong\u003e Polycarbonate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1653\" data-end=\"1700\"\u003e\n\u003cp data-start=\"1655\" data-end=\"1700\"\u003e\u003cstrong data-start=\"1655\" data-end=\"1681\"\u003eOperating Temperature:\u003c\/strong\u003e –10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1701\" data-end=\"1732\"\u003e\n\u003cp data-start=\"1703\" data-end=\"1732\"\u003e\u003cstrong data-start=\"1703\" data-end=\"1725\"\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1733\" data-end=\"1773\"\u003e\n\u003cp data-start=\"1735\" data-end=\"1773\"\u003e\u003cstrong data-start=\"1735\" data-end=\"1754\"\u003eCertifications:\u003c\/strong\u003e CE, UL, CSA, TÜV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1775\" data-end=\"1797\"\u003e\u003cstrong data-start=\"1779\" data-end=\"1795\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1798\" data-end=\"2019\"\u003e\n\u003cli data-start=\"1798\" data-end=\"1836\"\u003e\n\u003cp data-start=\"1800\" data-end=\"1836\"\u003eEmergency stop (E-Stop) monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1837\" data-end=\"1879\"\u003e\n\u003cp data-start=\"1839\" data-end=\"1879\"\u003eSafety gate and door interlock systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1880\" data-end=\"1928\"\u003e\n\u003cp data-start=\"1882\" data-end=\"1928\"\u003eLight curtain and presence sensor monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1929\" data-end=\"1975\"\u003e\n\u003cp data-start=\"1931\" data-end=\"1975\"\u003ePresses, robotics, and automated machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1976\" data-end=\"2019\"\u003e\n\u003cp data-start=\"1978\" data-end=\"2019\"\u003eGeneral machine safety control circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2021\" data-end=\"2061\"\u003e\u003cstrong data-start=\"2025\" data-end=\"2059\"\u003eWhy Choose the Banner IM-T-9A?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2062\" data-end=\"2309\"\u003e\n\u003cli data-start=\"2062\" data-end=\"2111\"\u003e\n\u003cp data-start=\"2064\" data-end=\"2111\"\u003eProven safety relay for dual-channel circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2112\" data-end=\"2152\"\u003e\n\u003cp data-start=\"2114\" data-end=\"2152\"\u003eReliable machine shutdown capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2153\" data-end=\"2197\"\u003e\n\u003cp data-start=\"2155\" data-end=\"2197\"\u003eCompact design saves control panel space\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2198\" data-end=\"2238\"\u003e\n\u003cp data-start=\"2200\" data-end=\"2238\"\u003eLED diagnostics simplify maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2239\" data-end=\"2309\"\u003e\n\u003cp data-start=\"2241\" data-end=\"2309\"\u003eTrusted Banner quality and compliance with global safety standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2311\" data-end=\"2330\"\u003e\u003cstrong data-start=\"2315\" data-end=\"2328\"\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2331\" data-end=\"2490\"\u003eProtect your automation systems with the \u003cstrong data-start=\"2372\" data-end=\"2390\"\u003eBanner IM-T-9A\u003c\/strong\u003e — a robust safety relay module delivering dependable, standards-compliant machine safety control.\u003c\/p\u003e","brand":"Banner Engineering","offers":[{"title":"Default Title","offer_id":50640037380374,"sku":"IM-T-9A","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/banner-im-t-9a-9664030.webp?v=1780276635","url":"https:\/\/ddpartssolution.com\/products\/banner-im-t-9a-safety-relay-module","provider":"DDPARTS SOLUTION","version":"1.0","type":"link"}