{"product_id":"balluff-bni00hl-profibus-io-module-16-inputs-ip67","title":"Balluff BNI00HL","description":"\u003ch2 data-start=\"290\" data-end=\"363\"\u003e\u003cstrong data-start=\"293\" data-end=\"363\"\u003eBalluff BNI00HL \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"365\" data-end=\"390\"\u003e\u003cstrong data-start=\"365\" data-end=\"382\"\u003eBalluff Code:\u003c\/strong\u003e \u003cspan\u003eBNI PG3-508-0C5-Z015\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"392\" data-end=\"410\"\u003e\u003cstrong data-start=\"396\" data-end=\"408\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"411\" data-end=\"711\"\u003eThe Balluff BNI00HL is a robust I\/O module designed for Profibus networks, offering 16 digital inputs in a decentralized, compact format. Built with M12 connectors and IP67-rated housing, it’s ideal for signal acquisition in demanding industrial environments where reliability and simplicity are key.\u003c\/p\u003e\n\u003ch3 data-start=\"713\" data-end=\"735\"\u003e\u003cstrong data-start=\"717\" data-end=\"733\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"736\" data-end=\"1082\"\u003e\n\u003cli data-start=\"736\" data-end=\"779\"\u003e\n\u003cp data-start=\"738\" data-end=\"779\"\u003eProfibus interface for easy integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"780\" data-end=\"807\"\u003e\n\u003cp data-start=\"782\" data-end=\"807\"\u003e16 digital inputs (PNP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"808\" data-end=\"853\"\u003e\n\u003cp data-start=\"810\" data-end=\"853\"\u003eM12 standard connectors for plug-and-play\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"854\" data-end=\"900\"\u003e\n\u003cp data-start=\"856\" data-end=\"900\"\u003eLEDs for status indication on each channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"901\" data-end=\"945\"\u003e\n\u003cp data-start=\"903\" data-end=\"945\"\u003eRugged IP67 housing for harsh conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"946\" data-end=\"987\"\u003e\n\u003cp data-start=\"948\" data-end=\"987\"\u003eShort-circuit and overload protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"988\" data-end=\"1029\"\u003e\n\u003cp data-start=\"990\" data-end=\"1029\"\u003eDIN rail or field mounting capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1030\" data-end=\"1082\"\u003e\n\u003cp data-start=\"1032\" data-end=\"1082\"\u003eOperates without control cabinet (decentralized)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1084\" data-end=\"1118\"\u003e\u003cstrong data-start=\"1088\" data-end=\"1116\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1119\" data-end=\"1459\"\u003e\n\u003cli data-start=\"1119\" data-end=\"1153\"\u003e\n\u003cp data-start=\"1121\" data-end=\"1153\"\u003e\u003cstrong data-start=\"1121\" data-end=\"1139\"\u003eCommunication:\u003c\/strong\u003e Profibus-DP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1154\" data-end=\"1187\"\u003e\n\u003cp data-start=\"1156\" data-end=\"1187\"\u003e\u003cstrong data-start=\"1156\" data-end=\"1167\"\u003eInputs:\u003c\/strong\u003e 16× digital (PNP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1188\" data-end=\"1231\"\u003e\n\u003cp data-start=\"1190\" data-end=\"1231\"\u003e\u003cstrong data-start=\"1190\" data-end=\"1205\"\u003eConnection:\u003c\/strong\u003e 8× M12 (A-coded), 4-pin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1232\" data-end=\"1273\"\u003e\n\u003cp data-start=\"1234\" data-end=\"1273\"\u003e\u003cstrong data-start=\"1234\" data-end=\"1253\"\u003eSupply Voltage:\u003c\/strong\u003e 24 V DC (nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1274\" data-end=\"1317\"\u003e\n\u003cp data-start=\"1276\" data-end=\"1317\"\u003e\u003cstrong data-start=\"1276\" data-end=\"1293\"\u003eCurrent Load:\u003c\/strong\u003e Max. 1.6 A per module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1318\" data-end=\"1349\"\u003e\n\u003cp data-start=\"1320\" data-end=\"1349\"\u003e\u003cstrong data-start=\"1320\" data-end=\"1342\"\u003eProtection Rating:\u003c\/strong\u003e IP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1350\" data-end=\"1378\"\u003e\n\u003cp data-start=\"1352\" data-end=\"1378\"\u003e\u003cstrong data-start=\"1352\" data-end=\"1365\"\u003eMaterial:\u003c\/strong\u003e PA 66, TPU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1379\" data-end=\"1412\"\u003e\n\u003cp data-start=\"1381\" data-end=\"1412\"\u003e\u003cstrong data-start=\"1381\" data-end=\"1394\"\u003eMounting:\u003c\/strong\u003e Field-mountable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1413\" data-end=\"1459\"\u003e\n\u003cp data-start=\"1415\" data-end=\"1459\"\u003e\u003cstrong data-start=\"1415\" data-end=\"1441\"\u003eOperating Temperature:\u003c\/strong\u003e –5 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1461\" data-end=\"1483\"\u003e\u003cstrong data-start=\"1465\" data-end=\"1481\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1484\" data-end=\"1661\"\u003e\n\u003cli data-start=\"1484\" data-end=\"1511\"\u003e\n\u003cp data-start=\"1486\" data-end=\"1511\"\u003eModular machine control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1512\" data-end=\"1552\"\u003e\n\u003cp data-start=\"1514\" data-end=\"1552\"\u003eDecentralized I\/O signal acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1553\" data-end=\"1588\"\u003e\n\u003cp data-start=\"1555\" data-end=\"1588\"\u003eMaterial handling and logistics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1589\" data-end=\"1627\"\u003e\n\u003cp data-start=\"1591\" data-end=\"1627\"\u003eFactory automation in tight spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1628\" data-end=\"1661\"\u003e\n\u003cp data-start=\"1630\" data-end=\"1661\"\u003eHarsh industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1663\" data-end=\"1700\"\u003e\u003cstrong data-start=\"1667\" data-end=\"1698\"\u003eWhy Choose Balluff BNI00HL?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1701\" data-end=\"1934\"\u003e\n\u003cli data-start=\"1701\" data-end=\"1748\"\u003e\n\u003cp data-start=\"1703\" data-end=\"1748\"\u003eSimplifies wiring and decentralizes control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1749\" data-end=\"1788\"\u003e\n\u003cp data-start=\"1751\" data-end=\"1788\"\u003eProfibus-ready for fast integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1789\" data-end=\"1834\"\u003e\n\u003cp data-start=\"1791\" data-end=\"1834\"\u003eDurable and sealed for harsh environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1835\" data-end=\"1880\"\u003e\n\u003cp data-start=\"1837\" data-end=\"1880\"\u003eLED diagnostics for quick troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1881\" data-end=\"1934\"\u003e\n\u003cp data-start=\"1883\" data-end=\"1934\"\u003eTrusted performance by Balluff automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1936\" data-end=\"1955\"\u003e\u003cstrong data-start=\"1940\" data-end=\"1953\"\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1956\" data-end=\"2103\"\u003eStreamline your fieldbus architecture with the Balluff BNI00HL — the rugged, compact I\/O module optimized for Profibus-based industrial automation.\u003cstrong data-start=\"2115\" data-end=\"2165\"\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Balluff","offers":[{"title":"Default Title","offer_id":50232427544854,"sku":"BNI00HL","price":2681.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/balluff-bni00hl-7483025.webp?v=1780251065","url":"https:\/\/ddpartssolution.com\/products\/balluff-bni00hl-profibus-io-module-16-inputs-ip67","provider":"DDPARTS SOLUTION","version":"1.0","type":"link"}