{"product_id":"balluff-bni00cn-io-link-hub-16-digital-inputs-ip67","title":"Balluff BNI00CN","description":"\u003ch2 data-start=\"277\" data-end=\"342\"\u003e\u003cstrong data-start=\"280\" data-end=\"342\"\u003eBalluff BNI00CN\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"344\" data-end=\"369\"\u003e\u003cstrong data-start=\"344\" data-end=\"361\"\u003eBalluff Code:\u003c\/strong\u003e \u003cspan\u003eBNI IOL-302-S02-Z012\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"371\" data-end=\"389\"\u003e\u003cstrong data-start=\"375\" data-end=\"387\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"390\" data-end=\"693\"\u003eThe Balluff BNI00CN is a robust IO-Link digital input hub designed for decentralized signal acquisition in industrial environments. With 16 digital input channels and full M12 connectivity, it enables simple and space-efficient wiring while maintaining IP67 protection for use in harsh field conditions.\u003c\/p\u003e\n\u003ch3 data-start=\"695\" data-end=\"717\"\u003e\u003cstrong data-start=\"699\" data-end=\"715\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"718\" data-end=\"1013\"\u003e\n\u003cli data-start=\"718\" data-end=\"754\"\u003e\n\u003cp data-start=\"720\" data-end=\"754\"\u003e16× digital inputs (PNP, Type 3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"755\" data-end=\"801\"\u003e\n\u003cp data-start=\"757\" data-end=\"801\"\u003eIO-Link interface for seamless integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"802\" data-end=\"850\"\u003e\n\u003cp data-start=\"804\" data-end=\"850\"\u003eM12 A-coded connectors for fast installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"851\" data-end=\"899\"\u003e\n\u003cp data-start=\"853\" data-end=\"899\"\u003eChannel-specific diagnostics and status LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"900\" data-end=\"929\"\u003e\n\u003cp data-start=\"902\" data-end=\"929\"\u003eRobust IP67-rated housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"930\" data-end=\"971\"\u003e\n\u003cp data-start=\"932\" data-end=\"971\"\u003eShort-circuit and overload protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"972\" data-end=\"1013\"\u003e\n\u003cp data-start=\"974\" data-end=\"1013\"\u003eEasy integration into control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1015\" data-end=\"1049\"\u003e\u003cstrong data-start=\"1019\" data-end=\"1047\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1050\" data-end=\"1412\"\u003e\n\u003cli data-start=\"1050\" data-end=\"1082\"\u003e\n\u003cp data-start=\"1052\" data-end=\"1082\"\u003e\u003cstrong data-start=\"1052\" data-end=\"1065\"\u003eProtocol:\u003c\/strong\u003e IO-Link (V1.1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1083\" data-end=\"1126\"\u003e\n\u003cp data-start=\"1085\" data-end=\"1126\"\u003e\u003cstrong data-start=\"1085\" data-end=\"1096\"\u003eInputs:\u003c\/strong\u003e 16× digital (PNP, sourcing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1127\" data-end=\"1182\"\u003e\n\u003cp data-start=\"1129\" data-end=\"1182\"\u003e\u003cstrong data-start=\"1129\" data-end=\"1144\"\u003eConnectors:\u003c\/strong\u003e 8× M12, A-coded (2 inputs per port)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1183\" data-end=\"1217\"\u003e\n\u003cp data-start=\"1185\" data-end=\"1217\"\u003e\u003cstrong data-start=\"1185\" data-end=\"1204\"\u003eVoltage Supply:\u003c\/strong\u003e 18–30 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1218\" data-end=\"1256\"\u003e\n\u003cp data-start=\"1220\" data-end=\"1256\"\u003e\u003cstrong data-start=\"1220\" data-end=\"1241\"\u003eMax Current Load:\u003c\/strong\u003e 2 A per port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1257\" data-end=\"1287\"\u003e\n\u003cp data-start=\"1259\" data-end=\"1287\"\u003e\u003cstrong data-start=\"1259\" data-end=\"1280\"\u003eEnclosure Rating:\u003c\/strong\u003e IP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1288\" data-end=\"1317\"\u003e\n\u003cp data-start=\"1290\" data-end=\"1317\"\u003e\u003cstrong data-start=\"1290\" data-end=\"1303\"\u003eMaterial:\u003c\/strong\u003e PA 66 \/ TPU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1318\" data-end=\"1364\"\u003e\n\u003cp data-start=\"1320\" data-end=\"1364\"\u003e\u003cstrong data-start=\"1320\" data-end=\"1346\"\u003eOperating Temperature:\u003c\/strong\u003e –5 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1365\" data-end=\"1412\"\u003e\n\u003cp data-start=\"1367\" data-end=\"1412\"\u003e\u003cstrong data-start=\"1367\" data-end=\"1380\"\u003eMounting:\u003c\/strong\u003e Field or machine installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1414\" data-end=\"1436\"\u003e\u003cstrong data-start=\"1418\" data-end=\"1434\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1437\" data-end=\"1600\"\u003e\n\u003cli data-start=\"1437\" data-end=\"1469\"\u003e\n\u003cp data-start=\"1439\" data-end=\"1469\"\u003eDistributed input monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1470\" data-end=\"1503\"\u003e\n\u003cp data-start=\"1472\" data-end=\"1503\"\u003eAssembly and conveyor systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1504\" data-end=\"1548\"\u003e\n\u003cp data-start=\"1506\" data-end=\"1548\"\u003eMachine tool and automation environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1549\" data-end=\"1600\"\u003e\n\u003cp data-start=\"1551\" data-end=\"1600\"\u003eIndustrial plants with harsh ambient conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1602\" data-end=\"1639\"\u003e\u003cstrong data-start=\"1606\" data-end=\"1637\"\u003eWhy Choose Balluff BNI00CN?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1640\" data-end=\"1882\"\u003e\n\u003cli data-start=\"1640\" data-end=\"1691\"\u003e\n\u003cp data-start=\"1642\" data-end=\"1691\"\u003eCompact and efficient IO-Link signal collection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1692\" data-end=\"1741\"\u003e\n\u003cp data-start=\"1694\" data-end=\"1741\"\u003eSimplifies wiring in decentralized automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1742\" data-end=\"1781\"\u003e\n\u003cp data-start=\"1744\" data-end=\"1781\"\u003eDurable build for rugged conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1782\" data-end=\"1830\"\u003e\n\u003cp data-start=\"1784\" data-end=\"1830\"\u003eReal-time diagnostics for faster maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1831\" data-end=\"1882\"\u003e\n\u003cp data-start=\"1833\" data-end=\"1882\"\u003eIdeal for scalable, flexible system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1884\" data-end=\"1903\"\u003e\u003cstrong data-start=\"1888\" data-end=\"1901\"\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1904\" data-end=\"2033\"\u003eStreamline your sensor connectivity with the Balluff BNI00CN — the efficient IO-Link hub for decentralized digital input control.\u003cstrong data-start=\"2045\" data-end=\"2095\"\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Balluff","offers":[{"title":"Default Title","offer_id":50232431378710,"sku":"BNI00CN","price":879.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/balluff-bni00cn-9888661.webp?v=1780251605","url":"https:\/\/ddpartssolution.com\/products\/balluff-bni00cn-io-link-hub-16-digital-inputs-ip67","provider":"DDPARTS SOLUTION","version":"1.0","type":"link"}