{"product_id":"balluff-bni004u","title":"Balluff BNI004U","description":"\u003ch2 data-end=\"343\" data-start=\"282\"\u003e\u003cstrong data-end=\"343\" data-start=\"285\"\u003eBalluff BNI004U\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"370\" data-start=\"345\"\u003e\u003cstrong data-end=\"362\" data-start=\"345\"\u003eBalluff Code:\u003c\/strong\u003e BNI PNT-502-105-Z015\u003c\/p\u003e\n\u003ch3 data-end=\"390\" data-start=\"372\"\u003e\u003cstrong data-end=\"388\" data-start=\"376\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"662\" data-start=\"391\"\u003eThe Balluff BNI004U is a rugged IO-Link I\/O module offering eight high-quality digital inputs. Designed for demanding industrial use, it combines robust IP67 protection with the flexibility and diagnostics of IO-Link, enabling efficient, decentralized signal acquisition.\u003c\/p\u003e\n\u003ch3 data-end=\"686\" data-start=\"664\"\u003e\u003cstrong data-end=\"684\" data-start=\"668\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1002\" data-start=\"687\"\u003e\n\u003cli data-end=\"733\" data-start=\"687\"\u003e\n\u003cp data-end=\"733\" data-start=\"689\"\u003e8 digital inputs (PNP, IEC 61131-2 Type 3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"771\" data-start=\"734\"\u003e\n\u003cp data-end=\"771\" data-start=\"736\"\u003eIO-Link interface (Class A, V1.1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"817\" data-start=\"772\"\u003e\n\u003cp data-end=\"817\" data-start=\"774\"\u003eM12 connectors for reliable sensor wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"866\" data-start=\"818\"\u003e\n\u003cp data-end=\"866\" data-start=\"820\"\u003eLEDs for input status and module diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"913\" data-start=\"867\"\u003e\n\u003cp data-end=\"913\" data-start=\"869\"\u003eRugged IP67 housing for harsh environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"955\" data-start=\"914\"\u003e\n\u003cp data-end=\"955\" data-start=\"916\"\u003eShort-circuit and overload protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1002\" data-start=\"956\"\u003e\n\u003cp data-end=\"1002\" data-start=\"958\"\u003eCompact form factor for machine installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1038\" data-start=\"1004\"\u003e\u003cstrong data-end=\"1036\" data-start=\"1008\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1336\" data-start=\"1039\"\u003e\n\u003cli data-end=\"1069\" data-start=\"1039\"\u003e\n\u003cp data-end=\"1069\" data-start=\"1041\"\u003e\u003cstrong data-end=\"1052\" data-start=\"1041\"\u003eInputs:\u003c\/strong\u003e 8 digital, PNP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1110\" data-start=\"1070\"\u003e\n\u003cp data-end=\"1110\" data-start=\"1072\"\u003e\u003cstrong data-end=\"1086\" data-start=\"1072\"\u003eInterface:\u003c\/strong\u003e IO-Link V1.1, Class A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1142\" data-start=\"1111\"\u003e\n\u003cp data-end=\"1142\" data-start=\"1113\"\u003e\u003cstrong data-end=\"1132\" data-start=\"1113\"\u003eSupply Voltage:\u003c\/strong\u003e 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1187\" data-start=\"1143\"\u003e\n\u003cp data-end=\"1187\" data-start=\"1145\"\u003e\u003cstrong data-end=\"1167\" data-start=\"1145\"\u003eMax Input Current:\u003c\/strong\u003e 0.5 A per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1223\" data-start=\"1188\"\u003e\n\u003cp data-end=\"1223\" data-start=\"1190\"\u003e\u003cstrong data-end=\"1209\" data-start=\"1190\"\u003eConnector Type:\u003c\/strong\u003e M12 A-coded\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1255\" data-start=\"1224\"\u003e\n\u003cp data-end=\"1255\" data-start=\"1226\"\u003e\u003cstrong data-end=\"1248\" data-start=\"1226\"\u003eProtection Rating:\u003c\/strong\u003e IP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1302\" data-start=\"1256\"\u003e\n\u003cp data-end=\"1302\" data-start=\"1258\"\u003e\u003cstrong data-end=\"1284\" data-start=\"1258\"\u003eOperating Temperature:\u003c\/strong\u003e –5 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1336\" data-start=\"1303\"\u003e\n\u003cp data-end=\"1336\" data-start=\"1305\"\u003e\u003cstrong data-end=\"1326\" data-start=\"1305\"\u003eHousing Material:\u003c\/strong\u003e Polyamide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1360\" data-start=\"1338\"\u003e\u003cstrong data-end=\"1358\" data-start=\"1342\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1562\" data-start=\"1361\"\u003e\n\u003cli data-end=\"1407\" data-start=\"1361\"\u003e\n\u003cp data-end=\"1407\" data-start=\"1363\"\u003eDecentralized sensing in modular machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1453\" data-start=\"1408\"\u003e\n\u003cp data-end=\"1453\" data-start=\"1410\"\u003eSensor integration in manufacturing lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1507\" data-start=\"1454\"\u003e\n\u003cp data-end=\"1507\" data-start=\"1456\"\u003ePackaging, sorting, and material handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1562\" data-start=\"1508\"\u003e\n\u003cp data-end=\"1562\" data-start=\"1510\"\u003eHarsh environments like wet, dusty, or outdoor areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1601\" data-start=\"1564\"\u003e\u003cstrong data-end=\"1599\" data-start=\"1568\"\u003eWhy Choose Balluff BNI004U?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1851\" data-start=\"1602\"\u003e\n\u003cli data-end=\"1655\" data-start=\"1602\"\u003e\n\u003cp data-end=\"1655\" data-start=\"1604\"\u003eSimplifies wiring and IO integration with IO-Link\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1709\" data-start=\"1656\"\u003e\n\u003cp data-end=\"1709\" data-start=\"1658\"\u003eMaximizes installation flexibility thanks to IP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1754\" data-start=\"1710\"\u003e\n\u003cp data-end=\"1754\" data-start=\"1712\"\u003eOffers rich diagnostics via onboard LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1798\" data-start=\"1755\"\u003e\n\u003cp data-end=\"1798\" data-start=\"1757\"\u003eEnables fast setup and machine redesign\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1851\" data-start=\"1799\"\u003e\n\u003cp data-end=\"1851\" data-start=\"1801\"\u003eBacked by Balluff’s trusted industrial performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1872\" data-start=\"1853\"\u003e\u003cstrong data-end=\"1870\" data-start=\"1857\"\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"2012\" data-start=\"1873\"\u003eUpgrade your automation network with the Balluff BNI004U — a compact, dependable IO-Link module for distributed digital signal acquisition.\u003c\/p\u003e","brand":"Balluff","offers":[{"title":"Default Title","offer_id":50238218699030,"sku":"BNI004U","price":1498.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/balluff-bni004u-2570478.webp?v=1780251007","url":"https:\/\/ddpartssolution.com\/products\/balluff-bni004u","provider":"DDPARTS SOLUTION","version":"1.0","type":"link"}