{"product_id":"host-automation-h2-ebc-ethernet-base-controller","title":"Host Automation H2-EBC","description":"\u003ch2 data-section-id=\"39yaa5\" data-start=\"385\" data-end=\"441\"\u003e\u003cstrong data-start=\"388\" data-end=\"441\"\u003eHost Automation H2-EBC \u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1dl56dh\" data-start=\"443\" data-end=\"461\"\u003e\u003cstrong data-start=\"447\" data-end=\"459\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"462\" data-end=\"832\"\u003eThe Host Automation H2-EBC is an \u003cstrong data-start=\"495\" data-end=\"523\"\u003eEthernet Base Controller\u003c\/strong\u003e designed for DL205 PLC systems, enabling seamless communication between controllers and Ethernet networks. It supports 10Base-T connectivity and integrates easily into distributed control architectures, providing reliable data exchange and real-time system monitoring. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"1hx1w1i\" data-start=\"834\" data-end=\"856\"\u003e\u003cstrong data-start=\"838\" data-end=\"854\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"857\" data-end=\"1168\"\u003e\n\u003cli data-section-id=\"m4c6th\" data-start=\"857\" data-end=\"903\"\u003e\n\u003cp data-start=\"859\" data-end=\"903\"\u003eEthernet base controller for DL205 systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13jeo8j\" data-start=\"904\" data-end=\"939\"\u003e\n\u003cp data-start=\"906\" data-end=\"939\"\u003e10Base-T Ethernet communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bonqkv\" data-start=\"940\" data-end=\"986\"\u003e\n\u003cp data-start=\"942\" data-end=\"986\"\u003eEnables remote I\/O and distributed control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14dxysx\" data-start=\"987\" data-end=\"1034\"\u003e\n\u003cp data-start=\"989\" data-end=\"1034\"\u003eSupports industrial communication protocols\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mayi9u\" data-start=\"1035\" data-end=\"1073\"\u003e\n\u003cp data-start=\"1037\" data-end=\"1073\"\u003eIntegrated RS-232 serial interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18vd1o1\" data-start=\"1074\" data-end=\"1118\"\u003e\n\u003cp data-start=\"1076\" data-end=\"1118\"\u003eCompact module for PLC rack installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qxendw\" data-start=\"1119\" data-end=\"1168\"\u003e\n\u003cp data-start=\"1121\" data-end=\"1168\"\u003eReliable operation in industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1880me3\" data-start=\"1170\" data-end=\"1204\"\u003e\u003cstrong data-start=\"1174\" data-end=\"1202\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1205\" data-end=\"1824\"\u003e\n\u003cli data-section-id=\"11l6mvo\" data-start=\"1205\" data-end=\"1241\"\u003e\n\u003cp data-start=\"1207\" data-end=\"1241\"\u003e\u003cstrong data-start=\"1207\" data-end=\"1232\"\u003eHost Automation Code:\u003c\/strong\u003e H2-EBC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ep2ys1\" data-start=\"1242\" data-end=\"1263\"\u003e\n\u003cp data-start=\"1244\" data-end=\"1263\"\u003e\u003cstrong data-start=\"1244\" data-end=\"1255\"\u003eSeries:\u003c\/strong\u003e DL205\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bmn3jj\" data-start=\"1264\" data-end=\"1306\"\u003e\n\u003cp data-start=\"1266\" data-end=\"1306\"\u003e\u003cstrong data-start=\"1266\" data-end=\"1279\"\u003eFunction:\u003c\/strong\u003e Ethernet Base Controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hvpsdl\" data-start=\"1307\" data-end=\"1345\"\u003e\n\u003cp data-start=\"1309\" data-end=\"1345\"\u003e\u003cstrong data-start=\"1309\" data-end=\"1327\"\u003eEthernet Type:\u003c\/strong\u003e 10Base-T (RJ45)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zt4bzr\" data-start=\"1346\" data-end=\"1410\"\u003e\n\u003cp data-start=\"1348\" data-end=\"1410\"\u003e\u003cstrong data-start=\"1348\" data-end=\"1362\"\u003eData Rate:\u003c\/strong\u003e 10 Mbps \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1roob3l\" data-start=\"1411\" data-end=\"1479\"\u003e\n\u003cp data-start=\"1413\" data-end=\"1479\"\u003e\u003cstrong data-start=\"1413\" data-end=\"1427\"\u003eProtocols:\u003c\/strong\u003e TCP\/IP, IPX \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tx3nqg\" data-start=\"1480\" data-end=\"1557\"\u003e\n\u003cp data-start=\"1482\" data-end=\"1557\"\u003e\u003cstrong data-start=\"1482\" data-end=\"1503\"\u003eSerial Interface:\u003c\/strong\u003e RS-232 (RJ12) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"q6kve1\" data-start=\"1558\" data-end=\"1639\"\u003e\n\u003cp data-start=\"1560\" data-end=\"1639\"\u003e\u003cstrong data-start=\"1560\" data-end=\"1587\"\u003eCommunication Distance:\u003c\/strong\u003e Up to 100 m \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"68ouuf\" data-start=\"1640\" data-end=\"1681\"\u003e\n\u003cp data-start=\"1642\" data-end=\"1681\"\u003e\u003cstrong data-start=\"1642\" data-end=\"1655\"\u003eMounting:\u003c\/strong\u003e PLC rack (DL205 system)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18a20oa\" data-start=\"1682\" data-end=\"1713\"\u003e\n\u003cp data-start=\"1684\" data-end=\"1713\"\u003e\u003cstrong data-start=\"1684\" data-end=\"1706\"\u003eProtection Rating:\u003c\/strong\u003e IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ve21zz\" data-start=\"1714\" data-end=\"1797\"\u003e\n\u003cp data-start=\"1716\" data-end=\"1797\"\u003e\u003cstrong data-start=\"1716\" data-end=\"1742\"\u003eOperating Temperature:\u003c\/strong\u003e 0 °C to +60 °C \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"292jzs\" data-start=\"1798\" data-end=\"1824\"\u003e\n\u003cp data-start=\"1800\" data-end=\"1824\"\u003e\u003cstrong data-start=\"1800\" data-end=\"1819\"\u003eCertifications:\u003c\/strong\u003e CE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"xdxar3\" data-start=\"1826\" data-end=\"1848\"\u003e\u003cstrong data-start=\"1830\" data-end=\"1846\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1849\" data-end=\"2005\"\u003e\n\u003cli data-section-id=\"9qjzb7\" data-start=\"1849\" data-end=\"1876\"\u003e\n\u003cp data-start=\"1851\" data-end=\"1876\"\u003eDistributed I\/O systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11wocm2\" data-start=\"1877\" data-end=\"1911\"\u003e\n\u003cp data-start=\"1879\" data-end=\"1911\"\u003eIndustrial automation networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"la0xzu\" data-start=\"1912\" data-end=\"1945\"\u003e\n\u003cp data-start=\"1914\" data-end=\"1945\"\u003ePLC-to-Ethernet communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"49fvhn\" data-start=\"1946\" data-end=\"1979\"\u003e\n\u003cp data-start=\"1948\" data-end=\"1979\"\u003eRemote monitoring and control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"dejgnt\" data-start=\"1980\" data-end=\"2005\"\u003e\n\u003cp data-start=\"1982\" data-end=\"2005\"\u003eManufacturing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1n1stv2\" data-start=\"2007\" data-end=\"2051\"\u003e\u003cstrong data-start=\"2011\" data-end=\"2049\"\u003eWhy Choose Host Automation H2-EBC?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2052\" data-end=\"2232\"\u003e\n\u003cli data-section-id=\"2a4flg\" data-start=\"2052\" data-end=\"2103\"\u003e\n\u003cp data-start=\"2054\" data-end=\"2103\"\u003eReliable Ethernet communication for PLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"a0g4mv\" data-start=\"2104\" data-end=\"2148\"\u003e\n\u003cp data-start=\"2106\" data-end=\"2148\"\u003eEasy integration with DL205 architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"n6pr0n\" data-start=\"2149\" data-end=\"2182\"\u003e\n\u003cp data-start=\"2151\" data-end=\"2182\"\u003eSupports remote I\/O expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11zhxlt\" data-start=\"2183\" data-end=\"2232\"\u003e\n\u003cp data-start=\"2185\" data-end=\"2232\"\u003eProven performance in industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"9pqy2m\" data-start=\"2234\" data-end=\"2253\"\u003e\u003cstrong data-start=\"2238\" data-end=\"2251\"\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2254\" data-end=\"2385\"\u003eUpgrade your control system with the Host Automation H2-EBC — reliable, efficient, and built for industrial Ethernet communication.\u003c\/p\u003e","brand":"Host Automation","offers":[{"title":"Default Title","offer_id":51129464815894,"sku":"H2-EBC","price":746.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/host-automation-h2-ebc-8833528.webp?v=1780271838","url":"https:\/\/ddpartssolution.com\/es\/products\/host-automation-h2-ebc-ethernet-base-controller","provider":"DDPARTS SOLUTION","version":"1.0","type":"link"}