{"product_id":"beckhoff-kl2542-dc-motor-bus-terminal","title":"Beckhoff KL2542","description":"\u003ch2 data-end=\"327\" data-start=\"266\"\u003e\u003cstrong data-end=\"327\" data-start=\"269\"\u003eBeckhoff KL2542\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-end=\"345\" data-start=\"329\"\u003e\u003cstrong data-end=\"345\" data-start=\"333\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"679\" data-start=\"346\"\u003eThe \u003cstrong data-end=\"369\" data-start=\"350\"\u003eBeckhoff KL2542\u003c\/strong\u003e is a \u003cstrong data-end=\"416\" data-start=\"375\"\u003e2-channel motion control Bus Terminal\u003c\/strong\u003e designed to directly operate DC brush motors in automation systems. It allows controllers to define motor speed or position through digital control values and supports encoder feedback for simple servo axis implementation. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"879\" data-start=\"681\"\u003eThis terminal integrates into Beckhoff Bus Terminal I\/O systems and includes overload, short-circuit protection, and diagnostic LEDs for fast troubleshooting. \u003cspan data-state=\"closed\" class=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"906\" data-start=\"886\"\u003e\u003cstrong data-end=\"906\" data-start=\"890\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1205\" data-start=\"907\"\u003e\n\u003cli data-end=\"946\" data-start=\"907\"\u003e\n\u003cp data-end=\"946\" data-start=\"909\"\u003eTwo-channel DC motor control output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1008\" data-start=\"947\"\u003e\n\u003cp data-end=\"1008\" data-start=\"949\"\u003eSupports speed and position control via controller values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1057\" data-start=\"1009\"\u003e\n\u003cp data-end=\"1057\" data-start=\"1011\"\u003eCompatible with incremental encoder feedback\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1108\" data-start=\"1058\"\u003e\n\u003cp data-end=\"1108\" data-start=\"1060\"\u003eBuilt-in overload and short-circuit protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1150\" data-start=\"1109\"\u003e\n\u003cp data-end=\"1150\" data-start=\"1111\"\u003eLED status indicators for diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1205\" data-start=\"1151\"\u003e\n\u003cp data-end=\"1205\" data-start=\"1153\"\u003eGalvanic isolation between K-bus and field voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1244\" data-start=\"1212\"\u003e\u003cstrong data-end=\"1244\" data-start=\"1216\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"1909\" data-start=\"1245\"\u003e\n\u003cli data-end=\"1266\" data-start=\"1245\"\u003e\n\u003cp data-end=\"1266\" data-start=\"1247\"\u003e\u003cstrong data-end=\"1257\" data-start=\"1247\"\u003eModel:\u003c\/strong\u003e KL2542\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1309\" data-start=\"1267\"\u003e\n\u003cp data-end=\"1309\" data-start=\"1269\"\u003e\u003cstrong data-end=\"1278\" data-start=\"1269\"\u003eType:\u003c\/strong\u003e DC motor output Bus Terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1347\" data-start=\"1310\"\u003e\n\u003cp data-end=\"1347\" data-start=\"1312\"\u003e\u003cstrong data-end=\"1334\" data-start=\"1312\"\u003eNumber of Outputs:\u003c\/strong\u003e 2 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1379\" data-start=\"1348\"\u003e\n\u003cp data-end=\"1379\" data-start=\"1350\"\u003e\u003cstrong data-end=\"1367\" data-start=\"1350\"\u003eLoad Voltage:\u003c\/strong\u003e 8…48 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1453\" data-start=\"1380\"\u003e\n\u003cp data-end=\"1453\" data-start=\"1382\"\u003e\u003cstrong data-end=\"1401\" data-start=\"1382\"\u003eOutput Current:\u003c\/strong\u003e Up to 3.5 A per channel (short-circuit protected)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1505\" data-start=\"1454\"\u003e\n\u003cp data-end=\"1505\" data-start=\"1456\"\u003e\u003cstrong data-end=\"1470\" data-start=\"1456\"\u003eLoad Type:\u003c\/strong\u003e DC brush motors, inductive loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1546\" data-start=\"1506\"\u003e\n\u003cp data-end=\"1546\" data-start=\"1508\"\u003e\u003cstrong data-end=\"1526\" data-start=\"1508\"\u003ePWM Frequency:\u003c\/strong\u003e Approx. 35–36 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1622\" data-start=\"1547\"\u003e\n\u003cp data-end=\"1574\" data-start=\"1549\"\u003e\u003cstrong data-end=\"1572\" data-start=\"1549\"\u003eControl Resolution:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1622\" data-start=\"1577\"\u003e\n\u003cli data-end=\"1595\" data-start=\"1577\"\u003e\n\u003cp data-end=\"1595\" data-start=\"1579\"\u003e12-bit current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1622\" data-start=\"1598\"\u003e\n\u003cp data-end=\"1622\" data-start=\"1600\"\u003e16-bit speed control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1675\" data-start=\"1623\"\u003e\n\u003cp data-end=\"1675\" data-start=\"1625\"\u003e\u003cstrong data-end=\"1644\" data-start=\"1625\"\u003eDigital Inputs:\u003c\/strong\u003e 2 inputs for limit detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1736\" data-start=\"1676\"\u003e\n\u003cp data-end=\"1736\" data-start=\"1678\"\u003e\u003cstrong data-end=\"1697\" data-start=\"1678\"\u003eEncoder Inputs:\u003c\/strong\u003e Supports incremental encoder systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1806\" data-start=\"1737\"\u003e\n\u003cp data-end=\"1806\" data-start=\"1739\"\u003e\u003cstrong data-end=\"1764\" data-start=\"1739\"\u003eElectrical Isolation:\u003c\/strong\u003e 500 V between K-bus and field potential\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1862\" data-start=\"1807\"\u003e\n\u003cp data-end=\"1862\" data-start=\"1809\"\u003e\u003cstrong data-end=\"1835\" data-start=\"1809\"\u003eOperating Temperature:\u003c\/strong\u003e Typically 0 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1909\" data-start=\"1863\"\u003e\n\u003cp data-end=\"1909\" data-start=\"1865\"\u003e\u003cstrong data-end=\"1878\" data-start=\"1865\"\u003eMounting:\u003c\/strong\u003e DIN rail Bus Terminal system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1936\" data-start=\"1916\"\u003e\u003cstrong data-end=\"1936\" data-start=\"1920\"\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"2129\" data-start=\"1937\"\u003e\n\u003cli data-end=\"1964\" data-start=\"1937\"\u003e\n\u003cp data-end=\"1964\" data-start=\"1939\"\u003eDC motor motion control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2007\" data-start=\"1965\"\u003e\n\u003cp data-end=\"2007\" data-start=\"1967\"\u003eConveyor and material handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2046\" data-start=\"2008\"\u003e\n\u003cp data-end=\"2046\" data-start=\"2010\"\u003eCompact servo axis implementations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2092\" data-start=\"2047\"\u003e\n\u003cp data-end=\"2092\" data-start=\"2049\"\u003eIndustrial automation and machine control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2129\" data-start=\"2093\"\u003e\n\u003cp data-end=\"2129\" data-start=\"2095\"\u003eRobotics and positioning systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2166\" data-start=\"2136\"\u003e\u003cstrong data-end=\"2166\" data-start=\"2140\"\u003eWhy Choose This Model?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-end=\"2455\" data-start=\"2167\"\u003e\n\u003cli data-end=\"2226\" data-start=\"2167\"\u003e\n\u003cp data-end=\"2226\" data-start=\"2169\"\u003eAllows direct DC motor operation without external drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2285\" data-start=\"2227\"\u003e\n\u003cp data-end=\"2285\" data-start=\"2229\"\u003eSupports encoder feedback for improved motion accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2340\" data-start=\"2286\"\u003e\n\u003cp data-end=\"2340\" data-start=\"2288\"\u003eIntegrated protection increases system reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2396\" data-start=\"2341\"\u003e\n\u003cp data-end=\"2396\" data-start=\"2343\"\u003eCompact Bus Terminal design simplifies installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2455\" data-start=\"2397\"\u003e\n\u003cp data-end=\"2455\" data-start=\"2399\"\u003eSeamless integration into Beckhoff I\/O and PLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2479\" data-start=\"2462\"\u003e\u003cstrong data-end=\"2479\" data-start=\"2466\"\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"2625\" data-start=\"2480\"\u003eThe \u003cstrong data-end=\"2503\" data-start=\"2484\"\u003eBeckhoff KL2542\u003c\/strong\u003e is a reliable and compact solution for controlling DC motors with integrated diagnostics and encoder feedback capability.\u003c\/p\u003e","brand":"Beckhoff","offers":[{"title":"Default Title","offer_id":51023927902486,"sku":"KL2542","price":470.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/beckhoff-kl2542-2046645.jpg?v=1780273938","url":"https:\/\/ddpartssolution.com\/es\/products\/beckhoff-kl2542-dc-motor-bus-terminal","provider":"DDPARTS SOLUTION","version":"1.0","type":"link"}