{"title":"Fluke","description":"\u003cp data-start=\"193\" data-end=\"602\" style=\"text-align: left;\"\u003eDiscover our complete selection of Fluke test and measurement equipment, trusted worldwide for accuracy, durability, and reliability. From digital multimeters, clamp meters, and power analyzers to thermal imagers and calibration tools, this collection brings together the most advanced instruments designed for professionals in industrial automation, electrical maintenance, and laboratory environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp data-start=\"604\" data-end=\"902\" style=\"text-align: left;\"\u003eWhether you need to troubleshoot, validate, or monitor systems, Fluke instruments deliver precise results and rugged performance to withstand demanding conditions. Shop our wide range of Fluke solutions and get the right tool to ensure safety, compliance, and efficiency in every application.\u003c\/p\u003e\n\u003chr\u003e","products":[{"product_id":"fluke-117-electricians-true-rms-multimeter","title":"Fluke 117","description":"\u003ch2\u003e\u003cstrong\u003eFluke 117 – Electrician’s Multimeter with Non-Contact Voltage\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 117\u003c\/strong\u003e is a compact true-RMS multimeter designed for electricians. Key features include auto AC\/DC voltage detection, non-contact voltage detection built in, low-impedance mode to avoid false “ghost voltages”, and a rugged build suitable for commercial, institutional, and industrial settings. It supports essential measurements like volts, current, resistance, frequency, and capacitance, with durability and safety in mind.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS measurement for accurate AC on non-linear loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-contact voltage detection (VoltAlert) built in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto AC\/DC voltage selection (AutoVolt)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-impedance mode to prevent ghost voltages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCAT III 600 V safety rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance, continuity, frequency, capacitance measurement functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge LED backlight for low-light workspaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin\/Max\/Average recording of signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 117\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum voltage between any terminal and earth ground: 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Category: CAT III, Pollution Degree 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Counts: 6,000 counts display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay update rate: ~4 per second; bar graph 33 segments (~32 updates\/s)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Volts Ranges \u0026amp; Resolution: 6.000 V \/ 0.001 V; 60.00 V \/ 0.01 V; 600.0 V \/ 0.1 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Volts (True-RMS) similar ranges, with accuracy:\u003cbr\u003e – 45-500 Hz: ±1.0% + 3 counts\u003cbr\u003e – 500 Hz-1 kHz: ±2.0% + 3 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity \/ Resistance: 600 Ω range, 1 Ω resolution; resistance ranges up to 40 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiode test range: ~2 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance measurement: ranges from ~1000 nF up to ~9999 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC\/DC Current (10 A range) with overload capacity (e.g. up to 20 A for short duration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 °C to +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Source: 9 V alkaline battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: ~400 hours (without backlight)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~550 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: approx. 167 × 84 × 46 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical contractors doing troubleshooting and installation work\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance in commercial buildings, schools, hospitals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting and measurement in industrial panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJobs where safety (non-contact voltage), reliability, and accuracy are important\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 117\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in non-contact voltage detection eliminates the need for a separate tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS ensures accurate readings even with distorted AC waveforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-impedance mode helps avoid misleading ghost voltage readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged build and excellent safety ratings for everyday use in challenging environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 117 is part of Fluke’s Electrician DMM line and is available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50533964284182,"sku":"Fluke 117","price":422.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-117-5223791.webp?v=1780276505"},{"product_id":"fluke-87v-industrial-true-rms-multimeter","title":"Fluke 87V","description":"\u003ch2\u003e\u003cstrong\u003eFluke 87V – Industrial True-RMS Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 87V\u003c\/strong\u003e multimeter is designed for demanding industrial and electrical work. It offers high precision, enhanced input protection, and functions tailored for troubleshooting motor drives, power distribution, and electromechanical installations. It includes a selectable low-pass filter to reduce noise from variable frequency drives (VFDs), a built-in thermometer, bright backlighting, and robust safety and durability features.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS AC and DC measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1000 V maximum DC and AC voltage range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10 A current range (with 20 A for short duration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelectable low-pass filter for accurate readings on VFDs and noisy signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePeak capture to record transients as fast as 250 µs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in thermometer with included temperature probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog bar graph and large digit display with two-level backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh safety rating: CAT III 1000 V \/ CAT IV 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 87V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage DC: up to 1000 V; Accuracy ±(0.05 % + 1 count); Resolution down to 10 µV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage AC (True-RMS): up to 1000 V; Accuracy ±(0.7 % + 2 counts); Resolution 0.1 mV; Low-pass filter with 3 dB @ 1 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent DC: up to 10 A (20 A for up to 30 seconds); Accuracy ±(0.2 % + 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent AC (True-RMS): up to 10 A (20 A for short duration); Accuracy ±(1.0 % + 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance: up to 50 MΩ; Accuracy ±(0.2 % + 1 count)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance: up to 9,999 µF; Accuracy ±(1 % + 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency: up to 200 kHz; Accuracy ±(0.005 % + 1 count)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDuty Cycle: up to 99.9 %; Resolution 0.1 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Measurement (with probe): -200 °C to +1090 °C (excluding probe)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Probe Range: -40 °C to +260 °C; Either ±2.2 °C or ±2 % whichever greater\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay Modes: 6,000 counts standard; 19,999 counts in high-resolution mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog Bar Graph: 32 segments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Alerts: Audible warning if test leads are placed incorrectly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Standards: CAT III 1000 V \/ CAT IV 600 V; overvoltage protection for spikes (\u0026gt;8000 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -20 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrop test: Survives 1 meter drop (with holster)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration: Meets MIL-PRF-28800 Class 2 standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Source: 9 V battery (alkaline), battery life ~400 hours without backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize \u0026amp; Weight: Approx. 201 × 98 × 52 mm; ~355 g (body only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTroubleshooting motor drives and adjustable frequency drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower distribution and industrial electrical maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectromechanical equipment diagnostics in noisy environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironments requiring high safety ratings and input protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 87V\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eExcellent accuracy and resolution for both AC and DC signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-pass filter and peak capture to handle electrical noise and fast transients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in thermometer and versatility reduce need for additional tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged safety design and protection increase reliability on the job\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 87V is part of Fluke’s Industrial Multimeter line and is available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50533975621910,"sku":"Fluke 87V","price":956.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-87v-3751453.webp?v=1780279151"},{"product_id":"fluke-179-true-rms-multimeter-1000v","title":"Fluke 179","description":"\u003ch2\u003e\u003cstrong\u003eFluke 179 – Industrial True-RMS Digital Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 179\u003c\/strong\u003e is a rugged, full-featured digital multimeter designed for HVAC, electrical, industrial, and electronics work. It includes true-RMS measurements, a built-in thermometer, analog bar graph, backlight for low-light conditions, and both manual and auto ranging. With high safety ratings and robust protection, it’s made for demanding field use.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS for accurate AC\/DC readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures up to 1000 V (AC\/DC) and 10 A (AC\/DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemp measurement from -40 °C to +400 °C with included thermocouple\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance up to 50 MΩ; capacitance up to 10 000 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency up to 100 kHz; analog bar graph\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin\/Max\/Average recording, Display Hold and Auto Hold\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBacklit display; robust over-molded construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 179\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage DC: up to 1000 V; accuracy ±(0.09 % + 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage AC (True-RMS): up to 1000 V; accuracy ±(1.0 % + 3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent DC: up to 10 A; accuracy ±(1.0 % + 3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent AC: up to 10 A; accuracy ±(1.5 % + 3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance: up to 50 MΩ; accuracy ±(0.9 % + 1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance: up to 10 000 µF; accuracy ±(1.2 % + 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency: up to 100 kHz; accuracy ±(0.1 % + 1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature (with probe): -40 °C … +400 °C; accuracy ±(1.0 % + 10)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 °C … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -30 °C … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay Counts: 6,000 counts; updates ~4 times\/sec; bar-graph 33 segments (~40 updates\/sec)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Category: CAT III 1000 V; CAT IV 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: ~200 hours typical (alkaline, without backlight)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize: approx. 43 × 90 × 185 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~420 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical maintenance and troubleshooting in industrial settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC systems, motor and pump diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField work where a durable meter with a wide range and safety protections is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTasks requiring temperature measurement, capacitance, and true-RMS signal integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 179\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eExcellent accuracy in AC and DC across high voltages and currents\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide temperature range for harsh environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdvanced features like Min\/Max\/Average and built-in thermometer reduce need for extra tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong safety ratings and rugged design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 179 is part of Fluke’s 170-Series industrial multimeters. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534004588822,"sku":"Fluke 179","price":744.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-179-9840643.webp?v=1780276937"},{"product_id":"fluke-115-true-rms-field-technician-multimeter","title":"Fluke 115","description":"\u003ch2\u003e\u003cstrong\u003eFluke 115 – True-RMS Field Technician Digital Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 115\u003c\/strong\u003e is a true-RMS digital multimeter designed for field technicians. It provides accurate measurements for AC and DC voltage \u0026amp; current, resistance, frequency, capacitance, continuity and diode tests. It features a compact ergonomic design, large backlit display, and functions like Min\/Max\/Average to capture signal variations. It is safe for use up to 600 V environments and built for tough daily use.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS measurement for AC\/DC voltage and current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures up to 600 V (AC\/DC); up to 10 A current with overload protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance, continuity, frequency, capacitance, and diode test functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin\/Max\/Average with elapsed time to record fluctuations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge white LED backlight for low-light conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact, ergonomic one-hand operation design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCAT III 600 V safety rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e6,000-count resolution with bar graph display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 115\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage DC Ranges \u0026amp; Resolution: 600.0 mV \/ 0.1 mV; 6.000 V \/ 0.001 V; 60.00 V \/ 0.01 V; 600.0 V \/ 0.1 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage DC Accuracy: ±(0.5 % + 2 counts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage AC (True-RMS) Ranges: 6.000 V; 60.00 V; 600.0 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage AC Accuracy (45-500 Hz): ±(1.0 % + 3); at 500-1,000 Hz: ±(2.0 % + 3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent DC Ranges: 6.000 A; 10.00 A (20 A overload for 30 seconds)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent DC Accuracy: ±(1.0 % + 3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent AC (True-RMS) Ranges: 6.000 A; 10.00 A (20 A overload for 30 seconds)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent AC Accuracy (45-500 Hz): ±(1.5 % + 3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: up to 40 MΩ; various sub-ranges (600 Ω, 6 kΩ, etc.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity: Beeper (threshold approx. \u0026lt;20 Ω), detects opens\/shorts ≥ 500 µs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Range: up to 9,999 µF; accuracy varies by range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency (Voltage\/Current input): up to 50 kHz; accuracy approx. ±(0.1 % + 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiode Test: ~2.000 V range; accuracy ±(0.9 % + 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: 6,000 counts; 33-segment bar graph; updates ~4 \/ sec for digits; ~32 \/ sec for bar graph\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety: CAT III 600 V; Pollution Degree 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Source: 9 V alkaline battery; battery life ~400 hours (no backlight)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral electrical \u0026amp; electronic testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField service and troubleshooting of voltages, motors, and control circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC and appliance diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTasks needing capacitance and frequency measurement in addition to basic voltage\/current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 115\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS ensures accuracy even with nonsinusoidal waveforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOverload capability and durability for field environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFeature-rich (Min\/Max\/Average, capacitance, frequency, diode) for cost savings vs. buying separate tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafe and reliable with strong safety rating CAT III 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 115 is part of Fluke’s True-RMS multimeter line, made for field technicians. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534016844054,"sku":"Fluke 115","price":398.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-115-9449506.webp?v=1780276273"},{"product_id":"fluke-325-true-rms-clamp-meter","title":"Fluke 325","description":"\u003ch2\u003e\u003cstrong\u003eFluke 325 – True-RMS Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 325\u003c\/strong\u003e is a versatile clamp meter built for electricians in both commercial and residential settings. It measures AC\/DC current through its jaws (up to 400 A), AC\/DC voltage through leads, supports temperature and frequency measurement, and includes resistance\/continuity features. The meter offers true-RMS readings for accurate measurements with non-linear loads. It is rated for safety in CAT III 600 V \/ CAT IV 300 V environments and includes ergonomic design for field work.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS measurement for both AC and DC current and voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasure up to 400 A through the clamp for AC or DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage measurement (AC\/DC) to 600 V using test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature measurement via included K-type thermocouple (-10 °C to 400 °C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency measurement from 5 Hz to 500 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance up to 40 kΩ; continuity detection (≤ 30 Ω)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance measurement 0 … ~1,000 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin\/Max function to capture peak values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge backlit display for visibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlim ergonomic form for comfort and portability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCAT III 600 V \/ CAT IV 300 V safety rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo-year warranty included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 325\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Ranges: 40.00 A \/ 400.0 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Accuracy: ~2.0 % ±5 digits (45-65 Hz); ~2.5 % ±5 digits (65-400 Hz) (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-325?srsltid=AfmBOop2fVlkQdWijltxWErOBeJx3MeF4ELZoUOaO1l0ctEBS0fonMJH\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 325 True RMS Clamp Meter\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current Ranges: 40.00 A \/ 400.0 A; Accuracy ~2.0 % ±5 digits (\u003ca href=\"https:\/\/www.fluke-direct.com\/product\/fluke-325-true-rms-clamp-meter?utm_source=chatgpt.com\" title=\"Fluke 325 True RMS Clamp Meter, AC\/DC\"\u003eFluke Direct\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage (AC)\/Range: up to 600.0 V; Accuracy ~1.5 % ±5 digits (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-325?srsltid=AfmBOop2fVlkQdWijltxWErOBeJx3MeF4ELZoUOaO1l0ctEBS0fonMJH\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 325 True RMS Clamp Meter\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage (DC)\/Range: up to 600.0 V; Accuracy ~1.0 % ±5 digits (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-325?srsltid=AfmBOop2fVlkQdWijltxWErOBeJx3MeF4ELZoUOaO1l0ctEBS0fonMJH\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 325 True RMS Clamp Meter\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: 400.0 Ω \/ 4,000 Ω \/ 40.00 kΩ; Accuracy ~1.0 % ±5 digits (\u003ca href=\"https:\/\/docs.rs-online.com\/2962\/A700000009816788.pdf?utm_source=chatgpt.com\" title=\"Data Sheet: Fluke 325 True RMS Clamp Meter - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity: Beeper threshold ≤ 30 Ω (\u003ca href=\"https:\/\/www.fluke-direct.com\/product\/fluke-325-true-rms-clamp-meter?utm_source=chatgpt.com\" title=\"Fluke 325 True RMS Clamp Meter, AC\/DC\"\u003eFluke Direct\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Range: 0 … ~1,000 µF (\u003ca href=\"https:\/\/docs.rs-online.com\/2962\/A700000009816788.pdf?utm_source=chatgpt.com\" title=\"Data Sheet: Fluke 325 True RMS Clamp Meter - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Range: 5.0 … 500.0 Hz (\u003ca href=\"https:\/\/docs.rs-online.com\/2962\/A700000009816788.pdf?utm_source=chatgpt.com\" title=\"Data Sheet: Fluke 325 True RMS Clamp Meter - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContact Temperature Range: -10 °C … +400 °C via thermocouple probe (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-325?srsltid=AfmBOop2fVlkQdWijltxWErOBeJx3MeF4ELZoUOaO1l0ctEBS0fonMJH\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 325 True RMS Clamp Meter\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJaw Opening \/ Max Wire Diameter: 30 mm (600 MCM) (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-325?srsltid=AfmBOop2fVlkQdWijltxWErOBeJx3MeF4ELZoUOaO1l0ctEBS0fonMJH\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 325 True RMS Clamp Meter\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions (H × W × D): 207 × 75 × 34 mm (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-325?srsltid=AfmBOop2fVlkQdWijltxWErOBeJx3MeF4ELZoUOaO1l0ctEBS0fonMJH\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 325 True RMS Clamp Meter\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~283 g (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-325?srsltid=AfmBOop2fVlkQdWijltxWErOBeJx3MeF4ELZoUOaO1l0ctEBS0fonMJH\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 325 True RMS Clamp Meter\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety \/ Category Rating: CAT III 600 V \/ CAT IV 300 V (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-325?srsltid=AfmBOop2fVlkQdWijltxWErOBeJx3MeF4ELZoUOaO1l0ctEBS0fonMJH\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 325 True RMS Clamp Meter\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical troubleshooting in residential, commercial, and light industrial settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWork involving both AC and DC current \u0026amp; voltage measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature and frequency testing alongside electrical measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSituations where non-linear loads require true-RMS accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 325\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines multiple measurement functions (clamp current, voltage, temperature, frequency) into one tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS ensures reliable readings for tricky electrical environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety rated for high-voltage environments (CAT III\/IV)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eErgonomic design supports field use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 325 is part of Fluke’s 300-series clamp meters. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534029066518,"sku":"Fluke 325","price":678.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-325-3439260.webp?v=1780277118"},{"product_id":"fluke-289-true-rms-logging-multimeter","title":"Fluke 289","description":"\u003ch2\u003e\u003cstrong\u003eFluke 289 – True-RMS Industrial Logging Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 289\u003c\/strong\u003e is an industrial-grade logging multimeter with advanced features for data capture and diagnosis. It offers true-RMS AC\/DC measurements, a low impedance voltage function to eliminate ghost voltages, and built-in logging memory with “TrendCapture” for graphing logged data onsite. Suitable for power distribution, automation, electronics, and electro-mechanical diagnostics. It includes standard safety ratings and durable build quality.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS AC and DC voltage and current measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoZ (“Low Impedance”) voltage mode to avoid ghost\/phantom voltages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrendCapture feature to graph logged data on-screen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAbility to log up to ~15,000 events or readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePeak capture (transients) as fast as 250 µs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelectable AC filter for smoothing noisy signals (e.g., from VFDs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative mode to subtract lead resistance for low-ohm or capacitance measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoZ and low pass filter both useful for accurate voltage\/frequency measurement in noisy environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 289\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Ranges \u0026amp; Resolution: 50.000 mV; 500.00 mV; 5.0000 V; 50.000 V; 500.00 V; 1000.0 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Accuracy: ~0.025 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage (True-RMS) Ranges: same as DC voltage ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Accuracy: ~0.4 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current Ranges \u0026amp; Resolution: 500.00 µA; 5000.0 µA; 50.000 mA; 400.00 mA; 5.0000 A; 10.000 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current Accuracy: ~0.05 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Ranges: same as DC current ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Accuracy: ~0.6 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Ranges: up to 500 MΩ, with multiple sub-ranges (e.g. 50 Ω to 500 MΩ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Ranges: up to 100 mF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Ranges: from ~99.999 Hz up to 999.99 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature (excluding probe): -200 °C to +1350 °C; accuracy ≈ 1.0 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Type: 6 × AA alkaline\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: ~100 hours for normal use; ~200 hours while logging mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -20 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Category: CAT III 1000 V \/ CAT IV 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMax Voltage between any terminal and earth ground: 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (H × W × D): ~22.2 × 10.2 × 6.0 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~871 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLogging voltage and current trends in industrial automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetecting intermittent faults or performance drifts over time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasuring noisy signals (from motor drives, power supplies) with low impedance mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectromechanical\/electrical maintenance, power distribution diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 289\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines logging, trend capture, and high accuracy in one handheld unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHelps find small anomalies before they become serious failures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow impedance voltage mode and selectable filtering improve measurement reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSolid safety ratings and rugged construction for industrial use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 289 is part of Fluke’s industrial logging multimeter line. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534043222294,"sku":"Fluke 289","price":1438.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-289-9460580.webp?v=1780277291"},{"product_id":"fluke-1587-fc-insulation-multimeter","title":"Fluke 1587 FC","description":"\u003ch2\u003e\u003cstrong\u003eFluke 1587 FC – Insulation Multimeter Combination Tool\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 1587 FC\u003c\/strong\u003e is a versatile instrument combining a full featured digital multimeter and an insulation tester in one rugged handheld unit. It offers true-RMS measurement, selectable insulation test voltages up to 1000 V, live circuit detection, VFD low-pass filtering, and connectivity via the Fluke Connect app. It’s designed for electricians, industrial maintenance, and preventive diagnostics where both insulation resistance and general electrical measurements are necessary.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation resistance range: 0.01 MΩ to 2 GΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS AC\/DC voltages and currents\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLive circuit detection (prevents insulation test if voltage \u0026gt;30 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVFD low-pass filter for AC voltage measurements under noisy loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePI\/DAR timed ratio tests for insulation diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures resistance, continuity, diode, frequency, capacitance, temperature, min\/max values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWireless data logging and trend tracking via Fluke Connect app\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable inputs with protection; rugged and portable design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 1587 FC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Resistance Range: 0.01 MΩ to 2 GΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Test Voltages: 50, 100, 250, 500, 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Test Accuracy: varies by test voltage (approx. ±(1.5 % to 3.0 % + 5 counts) depending on voltage) (\u003ca href=\"https:\/\/docs.rs-online.com\/d77c\/0900766b8148bfbd.pdf?utm_source=chatgpt.com\" title=\"Fluke 1587 FC\/1577 Insulation Multimeters - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Ranges: up to 1000 V; various ranges with true-RMS; resolution down to 0.1 mV on low end (\u003ca href=\"https:\/\/docs.rs-online.com\/d77c\/0900766b8148bfbd.pdf?utm_source=chatgpt.com\" title=\"Fluke 1587 FC\/1577 Insulation Multimeters - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Accuracy: approx. ±(1 % + 3) at 50-60 Hz on moderate ranges; ±(2 % + 3) at higher frequencies (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/insulation-testers\/fluke-1587-fc?srsltid=AfmBOopltVBX3SaSQPBmY3tJ9onP5qr6B-pKuugoj8z5J3ZWmCwN9hpn\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 1587 FC Insulation Tester Multimeter\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Ranges \u0026amp; Accuracy: up to 1000 V; accuracy ~ ±(0.09 % + 2 counts) on DC ranges (\u003ca href=\"https:\/\/docs.rs-online.com\/d77c\/0900766b8148bfbd.pdf?utm_source=chatgpt.com\" title=\"Fluke 1587 FC\/1577 Insulation Multimeters - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC\/DC Current Ranges: up to 400 mA; typical burden voltage ~2 mV\/mA; overload 600 mA for up to 2 minutes on current inputs (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/insulation-testers\/fluke-1587-fc?srsltid=AfmBOopltVBX3SaSQPBmY3tJ9onP5qr6B-pKuugoj8z5J3ZWmCwN9hpn\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 1587 FC Insulation Tester Multimeter\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range (DMM): up to 50 MΩ; accuracy ~ ±(0.9 % + 2) on lower ranges; ~ ±(1.5 % + 3) on highest ranges (\u003ca href=\"https:\/\/docs.rs-online.com\/d77c\/0900766b8148bfbd.pdf?utm_source=chatgpt.com\" title=\"Fluke 1587 FC\/1577 Insulation Multimeters - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Range: up to ~9999 µF; accuracy depends on range (\u003ca href=\"https:\/\/fluke.com.au\/en-sg\/product\/electrical-testing\/insulation-testers\/fluke-1587-fc?utm_source=chatgpt.com\" title=\"Fluke 1587 FC Insulation Tester Multimeter\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Measurement: approx. -40 °C to +537 °C; resolution ~0.1 °C; accuracy around ±(1 % + 10 counts) (\u003ca href=\"https:\/\/docs.rs-online.com\/d77c\/0900766b8148bfbd.pdf?utm_source=chatgpt.com\" title=\"Fluke 1587 FC\/1577 Insulation Multimeters - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Measurement (Voltage): ~99.99 Hz to ~99.99 kHz; accuracy approx. ±(0.1 % + 1 count) (\u003ca href=\"https:\/\/docs.rs-online.com\/d77c\/0900766b8148bfbd.pdf?utm_source=chatgpt.com\" title=\"Fluke 1587 FC\/1577 Insulation Multimeters - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-Impedance \/ Low-Pass Filtering: Provided for AC voltage under noisy or VFD environments (\u003ca href=\"https:\/\/docs.rs-online.com\/d77c\/0900766b8148bfbd.pdf?utm_source=chatgpt.com\" title=\"Fluke 1587 FC\/1577 Insulation Multimeters - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Impedance (Voltage): ~10 MΩ, \u0026lt;100 pF (\u003ca href=\"https:\/\/docs.rs-online.com\/d77c\/0900766b8148bfbd.pdf?utm_source=chatgpt.com\" title=\"Fluke 1587 FC\/1577 Insulation Multimeters - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLive Circuit Detection: inhibits insulation test if voltage \u0026gt;30 V present (\u003ca href=\"https:\/\/www.tequipment.net\/Fluke\/1587-FC\/Megohmmeter-\/-Insulation-Resistance-Testers\/?srsltid=AfmBOopMlGslWpPZN9vZ1g7dGpNtlmlF9465fqrdu1t8JayRIhs6NN98\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 1587 FC - 2 in 1 Insulation Tester \/ Multimeter\"\u003eTEquipment\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Type \u0026amp; Life: Alkaline batteries; meter mode ~1000 hours; insulation test mode ~1000 tests with fresh batteries under typical conditions (\u003ca href=\"https:\/\/docs.rs-online.com\/d77c\/0900766b8148bfbd.pdf?utm_source=chatgpt.com\" title=\"Fluke 1587 FC\/1577 Insulation Multimeters - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions (with holster): approx. 203 × 100 × 50 mm (\u003ca href=\"https:\/\/www.myflukestore.com\/product\/fluke-1587-fc-Insulation-multimeter-with-nist-cert?utm_source=chatgpt.com\" title=\"Fluke 1587 FC-NIST Insulation Multimeter,\"\u003eMy Fluke Store\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~624 g (\u003ca href=\"https:\/\/www.myflukestore.com\/product\/fluke-1587-fc-Insulation-multimeter-with-nist-cert?utm_source=chatgpt.com\" title=\"Fluke 1587 FC-NIST Insulation Multimeter,\"\u003eMy Fluke Store\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety \/ Ratings:\u003cbr\u003e - Measurement Categories: CAT III 1000 V \/ CAT IV 600 V (\u003ca href=\"https:\/\/www.tequipment.net\/Fluke\/1587-FC\/Megohmmeter-\/-Insulation-Resistance-Testers\/?srsltid=AfmBOopMlGslWpPZN9vZ1g7dGpNtlmlF9465fqrdu1t8JayRIhs6NN98\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 1587 FC - 2 in 1 Insulation Tester \/ Multimeter\"\u003eTEquipment\u003c\/a\u003e)\u003cbr\u003e - Live circuit detection, over-voltage protections, input fusing on current inputs (\u003ca href=\"https:\/\/docs.rs-online.com\/d77c\/0900766b8148bfbd.pdf?utm_source=chatgpt.com\" title=\"Fluke 1587 FC\/1577 Insulation Multimeters - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation resistance testing on motors, switchgear, transformers, and wiring installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreventive maintenance to detect insulation breakdown before failure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral-purpose multimeter functions in a single tool to reduce gear needed onsite\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting in environments with VFDs, moisture, or noisy electrical backgrounds where filtering and safety are important\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 1587 FC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines a high-performance insulation tester and a digital multimeter in one device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS, low-pass filters, and live detection improve accuracy and safety under difficult conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBroad test voltage range up to 1000 V and insulation resistance up to 2 GΩ support more demanding tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports wireless data logging and reporting via Fluke Connect for better documentation and trend tracking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1587 FC is part of Fluke’s Insulation Multimeter line. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534119145750,"sku":"Fluke 1587FC","price":1410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-1587-fc-4747305.webp?v=1780276931"},{"product_id":"fluke-1507-insulation-resistance-tester","title":"Fluke 1507","description":"\u003ch2\u003e\u003cstrong\u003eFluke 1507 – Insulation Resistance Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 1507\u003c\/strong\u003e is a rugged, compact handheld insulation resistance tester designed for contractors, industrial, and commercial electricians. It supports multiple test voltages, live-circuit detection, auto discharge of capacitive voltage, and includes a remote probe for repetitive or hard-to-reach measurements. Built for maintenance, commissioning, and troubleshooting of insulation systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures insulation resistance from 0.01 MΩ up to 10 GΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEarth bond resistance (lo-ohms continuity) using 200 mA source\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC\/DC voltage measurement up to 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLive circuit detection (prevent insulation testing if voltage \u0026gt;30 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote test probe for ease in tight or repetitive tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto discharge of capacitive voltage for user safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge backlit display for readability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCAT IV 600 V safety rating, compact and reliable design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: 1507\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Resistance Range: 0.01 MΩ to 10 GΩ (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/insulation-testers\/fluke-1507?srsltid=AfmBOoqnUVh3volgX3do_cCAUnzddhneRCCKcgpbyajrpdoKqqVEvRIj\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTest Voltages (Insulation): 50 V, 100 V, 250 V, 500 V, 1000 V (\u003ca href=\"https:\/\/www.myflukestore.com\/pdfs\/cache\/www.myflukestore.com\/fluke\/megohmmeter\/1507\/datasheet\/fluke_1507_megohmmeter_datasheet.pdf?utm_source=chatgpt.com\" title=\"1507\/1503 - Insulation Testers\"\u003eMy Fluke Store\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Test Accuracy: +20 %, -0 % on test voltage; accuracy depends on voltage and resistance range (\u003ca href=\"https:\/\/www.myflukestore.com\/pdfs\/cache\/www.myflukestore.com\/fluke\/megohmmeter\/1507\/datasheet\/fluke_1507_megohmmeter_datasheet.pdf?utm_source=chatgpt.com\" title=\"1507\/1503 - Insulation Testers\"\u003eMy Fluke Store\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort-Circuit Test Current (Insulation Mode): ~1 mA nominal (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/insulation-testers\/fluke-1507?srsltid=AfmBOoqnUVh3volgX3do_cCAUnzddhneRCCKcgpbyajrpdoKqqVEvRIj\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Capacitive Load: Up to ~1 µF (\u003ca href=\"https:\/\/docs.rs-online.com\/bf7e\/A700000010040882.pdf?utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEarth Bond \/ Continuity Range: 20.00 Ω; 200.0 Ω; 2000 Ω; 20.00 kΩ (\u003ca href=\"https:\/\/www.fluke-direct.com\/product\/fluke-1507-insulation-tester?utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester, 50 to 1000 V\"\u003eFluke Direct\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity Accuracy: ±(1.5 % + 3 digits) (\u003ca href=\"https:\/\/docs.rs-online.com\/bf7e\/A700000010040882.pdf?utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC\/DC Voltage Measurement Range: 0.1 V to 600 V (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/insulation-testers\/fluke-1507?srsltid=AfmBOoqnUVh3volgX3do_cCAUnzddhneRCCKcgpbyajrpdoKqqVEvRIj\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Accuracy: For AC 50-400 Hz, approx. ±(2 % + 3 digits) (\u003ca href=\"https:\/\/www.fluke-direct.com\/product\/fluke-1507-insulation-tester?utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester, 50 to 1000 V\"\u003eFluke Direct\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Impedance (Voltage): ~3 MΩ nominal, \u0026lt;100 pF (\u003ca href=\"https:\/\/docs.rs-online.com\/bf7e\/A700000010040882.pdf?utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOverload Protection: Up to 600 V AC or DC on voltage input (\u003ca href=\"https:\/\/docs.rs-online.com\/bf7e\/A700000010040882.pdf?utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester - RS Online\"\u003eRS Components\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -20 °C … +55 °C (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/insulation-testers\/fluke-1507?srsltid=AfmBOoqnUVh3volgX3do_cCAUnzddhneRCCKcgpbyajrpdoKqqVEvRIj\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 °C … +60 °C (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/insulation-testers\/fluke-1507?srsltid=AfmBOoqnUVh3volgX3do_cCAUnzddhneRCCKcgpbyajrpdoKqqVEvRIj\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (H × W × L): 5.0 × 10.0 × 20.3 cm (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/insulation-testers\/fluke-1507?srsltid=AfmBOoqnUVh3volgX3do_cCAUnzddhneRCCKcgpbyajrpdoKqqVEvRIj\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~550 g (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/insulation-testers\/fluke-1507?srsltid=AfmBOoqnUVh3volgX3do_cCAUnzddhneRCCKcgpbyajrpdoKqqVEvRIj\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Rating: IP40 (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/insulation-testers\/fluke-1507?srsltid=AfmBOoqnUVh3volgX3do_cCAUnzddhneRCCKcgpbyajrpdoKqqVEvRIj\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 1507 Insulation Resistance Tester\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTesting insulation resistance in motors, cables, transformers and electrical installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreventive maintenance to detect insulation degradation before failure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity\/earth bond testing for grounding systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallations where tight or repetitive insulation tests are required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 1507\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWide range of insulation voltages makes it versatile for many applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLive circuit detection and auto discharge improve safety for the user\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEarth bond continuity mode (200 mA) ensures strong verification of grounding connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact, robust design with clear display helps in field conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1507 is part of Fluke's insulation testers line. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534121701654,"sku":"Fluke 1507","price":1412.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-1507-4726554.webp?v=1780276338"},{"product_id":"fluke-789-processmeter-loop-calibrator","title":"Fluke 789","description":"\u003ch2\u003e\u003cstrong\u003eFluke 789 – Combined Loop Calibrator \u0026amp; True-RMS Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 789 ProcessMeter\u003c\/strong\u003e combines a precision digital multimeter (DMM) with a loop calibrator in one rugged handheld tool. It can measure, source, and simulate 4-20 mA loops, provide 24 V loop power, and supports true-RMS AC\/DC voltage up to 1000 V. Designed for industrial instrumentation, maintenance, and process control, it is especially useful for verifying, troubleshooting, and calibrating current loop devices and transmitters. It includes features like HART mode, dual display, advanced backlight, and durable design.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS DMM: measures AC\/DC voltage and current up to 1000 V \/ 1 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoop calibrator: sourcing \/ simulating 4-20 mA signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in 24 V loop power supply for transmitter testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelectable 250 Ω resistor for HART communications mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual bright display (simultaneous mA and % scale readout)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency measurement up to 20 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModes: Min\/Max\/Average, Hold, Relative, Diode test, Continuity beeper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto-step \/ manual coarse \/ fine \/ 25% \/ 100% span adjustments, auto ramp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged housing with accessible battery and fuse\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety rating: CAT III 1000 V \/ CAT IV 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 789\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage AC (True-RMS): up to 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage DC: up to 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent DC (measurement): up to 1 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent source\/simulate: 0-20 mA or 4-20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrive capability: up to 1200 Ω load at 20 mA; 24 V compliance in loop power mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: down to 0.001 mA in current measure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage DC Accuracy: ±0.1 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance: up to 40 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity: beeper threshold \u0026lt;100 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency: 0.5 Hz to 20 kHz; accuracy ±0.005 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: dual simultaneous readouts (mA and % scale) with bright backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (H × W × L): approx. 50 × 100 × 203 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~610 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower: 4 × AA alkaline batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery life: ~140 hours (meter mode), ~10 hours (sourcing 20 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -20 … +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental: up to 95% non-condensing humidity at 30 °C, shock tested to 1 m, vibration 2 g from 5-500 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Category: CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCalibrating and troubleshooting 4-20 mA instrumentation loops and transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifying wiring, sensors, and control loop devices without separate tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField maintenance in process plants, oil \u0026amp; gas, power generation, and automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupporting HART field devices with built-in resistor and loop power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 789\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines DMM \u0026amp; loop calibrator in one tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in loop power and HART mode reduce setup time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged safety ratings for industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual display and user-friendly interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 789 is part of Fluke’s ProcessMeter lineup. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534126059798,"sku":"Fluke 789","price":2598.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-789-3649225.webp?v=1780277003"},{"product_id":"fluke-ii900-industrial-acoustic-imager","title":"Fluke ii900","description":"\u003ch2\u003e\u003cstrong\u003eFluke ii900 – Leak Detection via Acoustic Imaging\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke ii900\u003c\/strong\u003e is a handheld acoustic imager made to help maintenance teams find leaks in compressed air, gas, and vacuum systems quickly—even in noisy industrial environments. It uses a large array of microphones to capture ultrasound frequencies, overlays a SoundMap on a visual image, and provides tools for leak sizing, cost estimation, image tagging, and reporting. Its rugged enclosure and long battery life make it suitable for field use.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e64 digital MEMS microphones for wide acoustic coverage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency detection band: ~2 kHz to 52 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e7-inch capacitive touchscreen LCD, sunlight readable with backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSoundMap overlay visualizes leak audio over live camera view\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLeakQ mode: estimates leak size, cost, and distance on the go\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCO₂ emission and cost reporting for leaks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImage and video capture: tagging, annotation, storing \u0026amp; exporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital zoom (3×), fixed focus lens, field of view ~63° ± 5°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto adjustable or manual frequency filtering to reduce background noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: ii900\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of Microphones: 64 digital MEMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Band: 2 kHz … 52 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetection Range: ~0.5 m to \u0026gt;70 m (ambient conditions dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField of View (camera): ~63° ± 5°\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: 7-inch LCD (1280 × 800 pixels), with capacitive touchscreen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCamera: built-in visible-light, fixed lens\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital Zoom: 3×\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrame Rate: ~25 fps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImage Storage: large internal storage, accepts \u0026gt;5000 pictures, \u0026gt;999 videos\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVideo Length per Clip: up to ~5 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVideo\/Image Formats: blended visual + SoundMap output in JPG\/PNG for images, MP4 for video\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSound Pressure Level Sensitivity: ranges from ~15 dB SPL to ~115 dB SPL at low-freq; higher levels at higher frequencies (approx. 40-133 dB SPL in upper bands)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery: field-replaceable Li-ion; includes spare; ~6 hours runtime per battery; ~3 hours to charge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight (with battery): ~1.8 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions (H × W × D): ~186 × 322 × 68 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 °C … +45 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -20 °C … +70 °C (batteries removed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 10 % to 95 %, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP Rating: IP40\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWarranty: 2 years\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety\/Compliance: IEC 61010-1, EMC (IEC 61326), RoHS, etc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLocating compressed air, vacuum, or gas leaks in industrial plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifying leak repairs and documenting savings in utilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspecting in noisy areas where traditional ultrasonic or acoustic sensors struggle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVisualizing and quantifying leak volume and cost on site\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke ii900\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFast visual leak detection with minimal training\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSoundMap overlay helps pinpoint precise leak location\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLeakQ cost\/volume estimation aids in prioritizing repairs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged design, sunlight-readable display, and long battery life for field reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke ii900 is part of Fluke’s industrial imaging line. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534128419094,"sku":"Fluke ii900","price":28998.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-ii900-7228958.webp?v=1780276932"},{"product_id":"fluke-323-true-rms-clamp-meter","title":"Fluke 323","description":"\u003ch2\u003e\u003cstrong\u003eFluke 323 – Basic True-RMS Clamp Meter for General Troubleshooting\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 323\u003c\/strong\u003e delivers rugged and reliable performance for basic electrical troubleshooting in commercial and residential installations. It includes True-RMS measurements to handle non-linear loads, a slim and ergonomic design for working in tight spaces, large easy-read display, and strong safety ratings. Perfect for checking current, voltage, continuity, and resistance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAC current measurement up to 400 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC and DC voltage measurement up to 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS voltage and current for accurate readings on non-linear signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance measurement with continuity detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge easy-to-read display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlim, ergonomic form factor for tight cable access\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHold function to freeze readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety rating: CAT IV 300 V \/ CAT III 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo-year warranty and soft carrying case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 323\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Range: up to 400.0 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Accuracy: ±2.0% + 5 digits (45-65 Hz); ±2.5% + 5 digits (65-400 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current: Not available on this model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Range: up to 600.0 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Accuracy: ±1.5% + 5 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Range: up to 600.0 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Accuracy: ±1.0% + 5 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Ranges: 400 Ω \/ 4000 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Accuracy: ±1.0% + 5 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity Beeper Threshold: ≤70 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJaw Opening \/ Max Conductor Size: 30 mm (600 MCM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (H × W × D): 207 × 75 × 34 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~265 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Rating: CAT IV 300 V \/ CAT III 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral electrical maintenance and troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifying load currents, AC\/DC voltages, and circuit continuity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse in tight panel assemblies or cable compartments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironments requiring rugged safety ratings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 323\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS ensures accurate readings on distorted or non-sine wave signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact design makes it easier to work in constrained spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong safety category ratings protect both tool and user\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDependable resistance and continuity functions add utility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 323 is part of Fluke’s 320-series clamp meters. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534139691286,"sku":"Fluke 323","price":318.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-323-1325093.webp?v=1780278203"},{"product_id":"fluke-t5-1000-voltage-current-tester","title":"Fluke T5-1000","description":"\u003ch2\u003e\u003cstrong\u003eFluke T5-1000 – Basic Voltage, Continuity, and Current Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke T5-1000\u003c\/strong\u003e is a compact, rugged tester that measures voltage, continuity, and current in a single handheld tool. It automatically detects AC or DC voltage up to 1000 V, measures AC current up to 100 A using OpenJaw™ without breaking the circuit, and includes a resistance function with continuity beeper. Built for durability, it withstands drops, tight workspaces, and everyday use in industrial and residential environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic AC\/DC voltage measurement up to 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOpenJaw™ clamp for AC current measurement up to 100 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance measurement up to 1000 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity beeper for quick checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetachable SlimReach probe tips for tight spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged housing with 3 m drop resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto-off function for extended battery life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety rating: CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke T5-1000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Range (AC\/DC): 0 … 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Accuracy: AC ±1.5 % + 2 counts; DC ±1 % + 1 count\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Range: 0 … 100 A (OpenJaw)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Accuracy: ±3 % + 3 counts (50\/60 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: 0 … 1000 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity Threshold: beeper below ~25 Ω, off above ~400 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJaw Opening: 12.9 mm (0.5 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMax Conductor Size: up to 1\/0 THHN cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –10 °C to +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: –30 °C to +60 °C (without batteries)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: 0–95 % non-condensing up to 30 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAltitude: up to 2000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrop Resistance: 3 m (10 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: 2 × AA batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: ~200 hours (zinc-chloride), ~400 hours (alkaline)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions (H × W × D): 203 × 51 × 30.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~300 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Category: CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQuick voltage, continuity, and current checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResidential, commercial, and industrial troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField testing in tight panel spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEveryday electrical maintenance with a rugged design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke T5-1000\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines three essential test functions in one tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOpenJaw™ lets you measure current without circuit interruption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged and reliable with strong safety ratings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact and easy to use with long battery life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke T5-1000 is part of Fluke’s electrical tester lineup. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534145327382,"sku":"Fluke T5-1000","price":332.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-t5-1000-5973867.webp?v=1780276512"},{"product_id":"fluke-175-true-rms-multimeter-1000v-10a","title":"Fluke 175","description":"\u003ch2\u003e\u003cstrong\u003eFluke 175 – Rugged Industrial True-RMS Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 175\u003c\/strong\u003e is built for professionals needing reliable, accurate measurements across electrical and electronic systems. It delivers true-RMS AC and DC voltage and current, plus resistance, capacitance, frequency, continuity, diode testing. It includes features like automatic\/manual ranging, Display Hold, Auto Hold, and Min\/Max-Average capture. Designed with safety in mind, with CAT IV \/ CAT III ratings and high overvoltage protection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS measurement for AC \u0026amp; DC voltage and current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures up to 1000 V (AC\/DC) and up to 10 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency, capacitance, resistance, continuity, diode test functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManual and autoranging modes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay Hold and Auto Hold functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin\/Max-Average recording mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged overmold case with built-in probe holders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLifetime warranty\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety rated CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 175\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Accuracy: ±(0.15 % + 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Maximum: 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Accuracy: ±(1.0 % + 3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Maximum: 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current Accuracy: ±(1.0 % + 3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current Maximum: 10 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Accuracy: ±(1.5 % + 3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Maximum: 10 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Accuracy: ±(0.9 % + 1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Maximum: 50 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Accuracy: ±(1.2 % + 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Maximum: 10,000 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Accuracy: ±(0.1 % + 1)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Maximum: 100 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 °C … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -30 °C … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity (non-condensing): 0-90 % at 0-35 °C; 0-70 % at 35-50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize: 43 × 90 × 185 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 420 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery: 9 V alkaline; battery life ~200 hours typical (without backlight)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical maintenance and troubleshooting in industrial and commercial settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerification of power supplies, motors, control circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePanel, wiring, and component testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse where ruggedness and safety are required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 175\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHigh voltage \u0026amp; current range with safety ratings suited for industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiverse measurement capabilities reduce need for multiple tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong accuracy and robust construction for long term reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 175 is part of Fluke’s True-RMS multimeter lineup. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534147588374,"sku":"Fluke 175","price":862.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-175-3902414.webp?v=1780276872"},{"product_id":"fluke-177-true-rms-multimeter-1000v-10a","title":"Fluke 177","description":"\u003ch2\u003e\u003cstrong\u003eFluke 177 – True-RMS Digital Multimeter with Backlight\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 177\u003c\/strong\u003e is a high-performance digital multimeter designed for electrical and electronic maintenance. It features true-RMS measurement for both AC and DC, a backlit display, and an analog-style bar graph for quick visual feedback. With manual and auto ranging, full measurement functions (voltage, current, resistance, capacitance, frequency, continuity, diode), this meter is built for professionals needing accurate, reliable readings in demanding environments. It carries robust safety ratings for high-voltage work.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS measurement for accurate AC and DC voltage \u0026amp; current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures up to 1000 V (AC\/DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent up to 10 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance, capacitance, frequency, diode, and continuity functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBacklit display \u0026amp; analog bar graph for better visibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManual and auto ranging modes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHold \u0026amp; Auto Hold; Min\/Max\/Average recording of measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eErgonomic overmold case with integrated holster\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLimited lifetime warranty\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 177\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Accuracy: ±(0.09 % + 2 digits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Range: up to 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Accuracy: ±(1.0 % + 3 digits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Range: up to 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current Accuracy: ±(1.0 % + 3 digits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current Range: up to 10 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Accuracy: ±(1.5 % + 3 digits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Range: up to 10 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Accuracy: ±(0.9 % + 1 digit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: up to 50 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Accuracy: ±(1.2 % + 2 digits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Range: up to 10,000 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Accuracy: ±(0.1 % + 1 digit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Range: up to 100 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: −10 °C … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: −30 °C … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity (non-condensing): 0-90 % at 0-35 °C; 0-70 % at 35-50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (H × W × D): 43 × 90 × 185 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~420 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life (typical alkaline, no backlight): ~200 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Ratings: CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical maintenance in industrial, commercial \u0026amp; residential settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting and diagnosing power supplies, motors, wiring faults\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEquipment calibration and verification under high-voltage conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse in dim lighting or harsh environments where backlighting helps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 177\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOutstanding accuracy with true-RMS for non-linear loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide voltage \u0026amp; current ranges, high safety ratings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFull feature set (capacitance, frequency, etc.) reduces need for multiple tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable build quality and lifetime warranty\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 177 is part of Fluke’s 170-Series True-RMS multimeters. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534150635798,"sku":"Fluke 177","price":710.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-177-3046935.webp?v=1780276457"},{"product_id":"fluke-t150-voltage-continuity-tester-6-690v","title":"Fluke T150","description":"\u003ch2\u003e\u003cstrong\u003eFluke T150 – Voltage \u0026amp; Continuity Electrical Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke T150\u003c\/strong\u003e is a durable two-pole tester for AC\/DC voltage and continuity measurements. It features LCD display, resistance measurement to core values, switchable load to suppress ghost voltages, and multiple ways to indicate voltage presence. Built for reliable use in tough field conditions with safety ratings suitable for industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage detection AC\/DC from ~6 V up to 690 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity and resistance testing up to 1999 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSwitchable load to help manage ghost voltages and test residual-current device (RCD) wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLCD display for voltage \/ resistance plus multiple LED indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTactile\/vibratory feedback, audible tone, and visual indicators for voltage presence\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBacklit display and buttons for low-light visibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSingle-pole phase test, phase-rotation indicator (for 3-phase systems)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProbe tip protection, secure probe docking; torch feature for dark areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP64 protection rating; rugged cable and build for field use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: T150\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Range (AC\/DC): 6 V to 690 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Detection Resolution: ±1 V on LCD; categorical thresholds for LEDs (~12 V, 24 V, 50 V, etc.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Accuracy (LCD): approx. ±(3 % reading + 5 digits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Impedance: ~200 kΩ under no-load conditions; lowered (~7 kΩ) when switchable load is on\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Range for measurement: 0 or 40 to 400 Hz (depending on function)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: 0 to 1999 Ω; continuity test up to ~400 kΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Accuracy: approx. ±(5 % reading + 10 digits) at 20 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResponse Time (LED indication): ≤ 0.5 s under standard voltage conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: 2 × AAA batteries (Micro \/ LR03)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Rating \/ Safety Category: CAT IV 600 V \/ CAT III 690 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Protection: IP64 (dust and water spray protection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -15 °C … +45 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -20 °C … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhysical Size \u0026amp; Weight: approx. 255 × 78 × 35 mm; ~0.27 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eConfirming presence or absence of voltage in circuits before maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChecking continuity, wiring connections, phase rotation in electrical installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifying outlets and device wiring under field conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUtility work where safety, visibility and ruggedness are required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke T150\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple indicators (LED, LCD, audible, vibration) ensure safe detection even with discharged batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance measurement adds diagnostic value beyond simple voltage checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSwitchable load helps reduce misleading readings and safer RCD testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP64 rating and rugged design make it suited for outdoor or harsh industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke T150 is part of Fluke’s basic voltage \u0026amp; continuity tester family. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534152143126,"sku":"Fluke T150","price":630.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-t150-6617193.webp?v=1780277945"},{"product_id":"fluke-t6-1000-electrical-tester-fieldsense","title":"Fluke T6-1000","description":"\u003ch2\u003e\u003cstrong\u003eFluke T6-1000 – FieldSense™ Electrical Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke T6-1000\u003c\/strong\u003e is an advanced electrical tester featuring FieldSense™ technology and an open-fork design that lets you measure AC voltage, current, and frequency without contacting a live metallic conductor. It supports true-rms readings for both voltage and current, works with wires up to AWG 4\/0 (≈ 120 mm²), and includes conventional test leads for DC \/ AC voltage and resistance functions. Built for industrial and commercial troubleshooting with rugged design, backlit display, and hold function.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFieldSense™ open-fork measurement of AC voltage, current \u0026amp; frequency without metallic contact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-rms AC voltage to 1000 V and AC current to 200 A through the fork\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlso supports DC and AC voltage \u0026amp; resistance using test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWorks with large conductors (wire up to AWG 4\/0 \/ 120 mm²) via wide fork opening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHold function to freeze displayed values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge backlit display for visibility in dim work environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDurable build and safety ratings suited for job sites\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: T6-1000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFieldSense AC Voltage (no test leads required): range up to 1000 V; resolution 1 V; accuracy ±(3 % + 3 counts) (45-66 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFieldSense AC Current (no test leads required): up to 200.0 A; resolution 0.1 A; accuracy ±(3 % + 3 counts) (45-66 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFieldSense Frequency: 45-66 Hz; resolution 1 Hz; accuracy ±(1 % + 2 counts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage with test leads: up to 1000 V; resolution 1 V; accuracy ±(1.5 % + 2 counts) (45-66 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage with test leads: up to 1000 V; resolution 1 V; accuracy ±(1 % + 2 counts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance with test leads: multiple ranges up to 100.0 kΩ; accuracy ±(1 % + 2 counts) across ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFork \/ Open Jaw Size: ~17.8 mm (≈ 0.7 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: approx. 61.1 × 259.3 × 43.8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~0.35 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 °C … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -30 °C … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAltitude (Operating): up to 2000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAltitude (Storage): up to 10,000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 0-90 % at 5-30 °C; lower limits at higher temps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Type: 2 × AA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: approx. 360 hours continuous, typical; ~200 hours if using FieldSense repeatedly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety \/ Measurement Category: CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompliance: IEC\/EN 61010-1, Pollution Degree 2; EMC per IEC\/EN 61326-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasuring AC voltage and current in live conductors without touching them directly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTroubleshooting electrical panels, motor connections, feeders with large cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFieldwork in dim or tight spaces where backlight and large display help\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJobs needing both contact and non-contact measurement capabilities in one tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke T6-1000\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eContactless FieldSense™ reduces risk and speeds up measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-rms ensures accurate results even with distorted or non-linear loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide fork opening supports large conductors common in industrial settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCombination of resistance and voltage test leads extend its usefulness beyond just AC measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke T6-1000 is part of Fluke’s lineup of advanced electrical testers. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534156730646,"sku":"Fluke T6-1000","price":556.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-t6-1000-1139704.webp?v=1780276385"},{"product_id":"fluke-62-max","title":"Fluke 62 MAX","description":"\u003ch2\u003e\u003cstrong\u003eFluke 62 MAX – Mini Infrared Thermometer\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 62 MAX\u003c\/strong\u003e is a tough, compact infrared thermometer for non-contact surface temperature measurements. Designed for electrical, HVAC, mechanical, and industrial environments, it includes laser targeting, backlighting, and rugged protection. It measures temperatures from -30 °C to 500 °C, offers good accuracy, and is built to withstand drops, dust, and moisture so it can endure harsh job site conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature range: -30 °C … +500 °C (-22 °F to 932 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10:1 distance-to-spot ratio for accurate targeting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSingle laser aiming for precise measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBacklit display for readings in dim conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin \/ Max \/ Average \/ Difference functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP54 rated for protection from dust and splashes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrop tested to 3 meters for rugged durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePowered by one standard AA battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight, ergonomic form factor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 62 MAX\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Range: -30 °C … +500 °C (-22 °F … +932 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: ±1.5 °C or ±1.5 % of reading, whichever is greater\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSub-ranges:\u003cbr\u003e - From -10 °C to 0 °C: ±2.0 °C\u003cbr\u003e - From -30 °C to -10 °C: ±3.0 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResponse Time (95 % of value): \u0026lt; 500 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpectral Response: 8 to 14 microns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmissivity Range: 0.10 to 1.00 (adjustable or fixed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptical Resolution (D:S): 10:1 (calculated at 90 % energy)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay Resolution: 0.1 °C (0.2 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRepeatability: ±0.8 % of reading or \u0026lt; ±1.0 °C, whichever is greater\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Source: 1 × AA battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: approx. 10 hours with laser \u0026amp; backlight on\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 °C to +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -20 °C to +60 °C (without battery)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~255 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize: approx. 175 × 85 × 75 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Humidity: 10 % to 90 % RH non-condensing at 30 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAltitude (operation): up to 2000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAltitude (storage): up to 12,000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP Rating: IP54 per IEC 60529\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrop Resistance: 3 m (9.8 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration \u0026amp; Shock: meets IEC vibration \u0026amp; shock standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety \/ Laser: Complies with IEC\/EN 61010-1 \u0026amp; class II laser safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eChecking surface temperatures on electrical panels, motors, pipes, HVAC equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePredictive maintenance and detecting hot spots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWorking in dusty, damp, or rough‐use environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSituations where non-contact temperature measurement is safer or more convenient\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 62 MAX\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCompact yet rugged design tolerates harsh job-site conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGood accuracy and range for many industrial and mechanical use cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFeatures like Min\/Max\/Average\/Difference help monitor trending or anomalies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP54 rating, drop resistance, and battery power make it portable and reliable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 62 MAX is part of Fluke’s IR thermometer lineup. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534158172438,"sku":"62 MAX","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-62-max-8075187.webp?v=1780277352"},{"product_id":"fluke-t5-600-voltage-continuity-current-tester","title":"Fluke T5-600","description":"\u003ch2\u003e\u003cstrong\u003eFluke T5-600 – Voltage, Continuity, and Current Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke T5-600\u003c\/strong\u003e is a compact tester that combines voltage, continuity, and current functions in one rugged tool. It automatically detects AC or DC voltage up to 600 V, measures AC current up to 100 A using its OpenJaw™ clamp, and checks continuity and resistance quickly. Built tough with drop resistance and SlimReach probes, it’s ideal for everyday electrical troubleshooting.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures AC current up to 100 A with OpenJaw™ clamp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic AC\/DC voltage detection up to 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance measurement up to 1000 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAudible continuity beeper for quick checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetachable SlimReach probes for confined spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged design tested to withstand 3 m drop\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto-off to extend battery life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated probe storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety rated CAT III 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: T5-600\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Range: 0 to 600 V AC\/DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Accuracy: AC ±1.5 % + 2 digits; DC ±1 % + 1 digit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Range (OpenJaw): 0 to 100 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Accuracy (50\/60 Hz): ±3 % + 3 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: 0 to 1000 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity Threshold: beeper on \u0026lt; 25 Ω; off \u0026gt; 400 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJaw Opening: 12.9 mm (0.5 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMax Conductor Size: up to 1\/0 THHN cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –10 °C to +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: –30 °C to +60 °C (without batteries)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity (non-condensing): 0–95 % up to 30 °C, derating at higher temps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrop Resistance: 3 m (10 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Rating: CAT III 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: 2 × AA batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: ~200 hours (zinc-chloride), ~400 hours (alkaline)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions (H × W × D): 203 × 51 × 30.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~300 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eResidential, commercial, and industrial troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuick checks for voltage, current, and continuity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafe current testing without breaking the circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFieldwork where durability and reliability matter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke T5-600\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines three essential test functions in one tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOpenJaw™ technology simplifies current testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact, rugged design ideal for daily use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong safety rating for dependable performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke T5-600 is part of Fluke’s basic electrical tester lineup. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534249627926,"sku":"Fluke T5600","price":270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-t5-600-8099827.webp?v=1780277345"},{"product_id":"fluke-376-true-rms-ac-dc-clamp-meter-iflex","title":"Fluke 376","description":"\u003ch2\u003e\u003cstrong\u003eFluke 376 – AC DC Clamp Meter with Extended Range\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 376\u003c\/strong\u003e is a high-performance clamp meter designed for industrial electricians and maintenance technicians. It measures true-RMS AC and DC voltage and current, with extended range through the iFlex flexible current probe. Features include inrush capture, low-pass filter for variable frequency drives, and resistance and capacitance measurement. Built tough for demanding environments with CAT safety ratings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS measurement for both AC and DC voltage and current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage up to 1000 V AC or DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent up to 1000 A with jaw clamp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 2500 A AC with included iFlex flexible probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eiFlex probe allows access to large conductors and tight spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInrush capture for motor startup analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-pass filter for accurate VFD measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance, capacitance, continuity testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin, Max, and Average recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge backlit display with ergonomic design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 376\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current (Jaw): up to 1000 A, accuracy ~2 percent ± 5 digits (10–100 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current (iFlex): up to 2500 A, accuracy ~3 percent ± 5 digits (5–500 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current: up to 1000 A, accuracy ~2 percent ± 5 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage: up to 1000 V, accuracy ~1.5 percent ± 5 digits (20–500 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage: up to 1000 V, accuracy ~1 percent ± 5 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: up to 60 kΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Range: up to 1000 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Range: 5 Hz to 500 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJaw Opening: 34 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eiFlex Cable Length: 1.8 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 10 °C to 50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity (non-condensing): up to 90 percent at 10–30 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAltitude (Operating): up to 3000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Rating: CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial troubleshooting with high current and voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasuring current in large conductors with flexible probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStartup and inrush current diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical panels and equipment powered by VFDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance checks with capacitance and resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 376\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eExtended current range with iFlex probe up to 2500 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS accuracy for noisy or distorted signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInrush capture for analyzing equipment startup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged design with strong safety certification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 376 is part of the 370-series clamp meters. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534253527318,"sku":"Fluke 376","price":828.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-376-4270861.webp?v=1780277717"},{"product_id":"fluke-116-hvac-multimeter-temperature-microamp","title":"Fluke 116","description":"\u003ch2\u003e\u003cstrong\u003eFluke 116 – HVAC Digital Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 116\u003c\/strong\u003e is designed for HVAC\/R technicians. It combines true-RMS AC\/DC voltage and current measurement up to 600 V, a built-in thermometer for temperature readings, and microamp measurement for flame sensors. It includes functions for resistance, continuity, frequency, and capacitance. Its rugged design and safety rating make it suitable for demanding field service work in HVAC systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS measurement for AC and DC voltage and current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in thermometer (Type-K) for measuring temperature from -40 °C to +400 °C (or -40 °F to +752 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMicroamp input for testing flame sensors down in µA ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow input impedance “Lo-Z” mode to prevent ghost voltage readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge white LED backlit display for visibility in dim work areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures resistance, continuity with audible beeper, frequency, and capacitance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin\/Max\/Average to record signal fluctuations over time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact ergonomics for one-handed use, rugged housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety rating: CAT III 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 116\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum AC\/DC Voltage: 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC\/DC Voltage Accuracy: 2.0 % + 3 counts (45-500 Hz DC mode), 4.0 % + 3 counts (500 Hz-1 kHz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Millivolts True-RMS Range: 600.0 mV; Resolution: 0.1 mV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity Test Range: 600 Ω; Indicates beeper on less than 20 Ω, off greater than 250 Ω; Detects opens or shorts of 500 µs or longer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Ranges: 600 Ω; 6 kΩ; 60 kΩ; 600 kΩ; 6 MΩ; 40 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Accuracy: ~0.9 % + 1 count on lower ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiode Test: up to 2.000 V; Resolution 0.001 V; Accuracy ~0.9 % + 2 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Ranges: from ~1 nF through ~9999 µF; Accuracy varies with range (typical ~0.9 % for smaller, larger error for \u0026gt;1000 µF)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature (Type-K Thermocouple): Range -40 °C to +400 °C; Resolution 0.1 °C; Accuracy ~1 % + offset\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMicroamp Ranges: AC\/DC µA ranges to 600.0 µA; Resolution 0.1 µA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency (Voltage Input): up to ~50.00 kHz; Accuracy ~0.1 % + 2 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: 6000 counts, white LED backlight, updates ~4 times per second; bar graph ~33 segments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 °C to +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize: ~167 × 84 × 46 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~550 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWarranty: 3 years\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnosing HVAC system electrical circuits, flame sensor behavior, and temperature conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifying voltage, current, frequency in heating, ventilation, air conditioning and refrigeration equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapturing temperature trends and fluctuations with Min\/Max\/Average functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField work where ruggedness, accuracy and safety are essential\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 116\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines temperature and microamp measurements specific to HVAC technician needs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS and Lo-Z features improve reliability in noisy or complex electrical environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong safety rating ensures dependable performance in high voltage situations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDurable build and backlight display make it suitable for both indoor and harsher field use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 116 belongs to Fluke’s HVAC\/R multimeter series. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534256115990,"sku":"Fluke 116","price":448.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-116-1455405.webp?v=1780277236"},{"product_id":"fluke-1662-multifunction-installation-tester","title":"Fluke 1662","description":"\u003ch2\u003e\u003cstrong\u003eFluke 1662 – Multifunction Installation Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 1662\u003c\/strong\u003e is a reliable installation tester built for everyday electrical installation verification. It measures AC\/DC voltage and frequency, checks wiring polarity including broken neutral conductors, tests insulation and loop and line resistance, and includes RCD test routines. Designed for safety, speed and compliance with local installation standards, it comes with practical features like auto-start for certain tests and memory (Z-Max) for loop tests.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAC\/DC voltage measurement with true-rms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring polarity check to detect broken neutral wires\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation resistance test at multiple voltages (100 V, 250 V, 500 V, 1000 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoop and line impedance tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProspective earth fault current calculation and prospective short-circuit current calculation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRCD (Residual Current Device) trip time and current measurement, including variable current and ramp test\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhase sequence indicator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMemory for maximum loop values (Z-Max)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eZero adapter to compensate for test leads and mains cord resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHard carrying case, remote control probe, lead set and strap included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 1662\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Range: up to 500 V AC\/DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Resolution: 0.1 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Accuracy (45-66 Hz): ±0.8 % + 3 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Impedance: 360 kΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOverload Protection: 660 V rms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity Testing (Autoranging): 20 Ω \/ 200 Ω \/ 2000 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity Resolution: 0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOpen Circuit Voltage for continuity: greater than 4 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Test Voltages: 100 V, 250 V, 500 V, 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Resistance Ranges: up to 100 MΩ depending on test voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Resolution: depending on range, down to 0.01 MΩ or 0.1 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoop and Line Impedance Range and Resolution: includes high current mΩ mode, autorange 10 Ω \/ 20 Ω \/ 200 Ω \/ 2000 Ω with corresponding resolutions 0.001 Ω \/ 0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProspective Earth Fault Current \/ Prospective Short-Circuit Current Range: up to tens of kiloamps (institutional values)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRCD Types Tested: Type AC, Type A, Type G, Type S\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRCD Trip Current Range: includes 10, 30, 100, 300, 500, 1000 mA depending on type and mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRCD Trip Time Ranges: varies by type (AC \/ A \/ S)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhase Sequence Indication: for voltages between ~100-500 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: 6 × AA batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (L × W × H): 10 × 25 × 12.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight (with batteries): ~1.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSealing \/ Protection: IP-40\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Category: CAT III 500 V \/ CAT IV 300 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandards Compliance: EN\/IEC 61010-1, relevant installation safety standards EN61557-1 to EN61557-7 and EN61557-10\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical installations verification in residential, commercial and light industrial settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRCD test routines for safety compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting insulation integrity during commissioning or safety inspections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifying loop\/line resistance and fault current capabilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTroubleshooting wiring polarity issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 1662\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBroad test coverage in one device reduces need for multiple tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-rms voltage and frequency give accurate readings under varied supply conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRCD testing and loop memory features save time on repeat jobs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged design built for field conditions with accessory kit included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1662 is part of Fluke’s installation tester series. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003c\/h4\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534259360022,"sku":"Fluke 1662","price":3910.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-1662-2017549.webp?v=1780277766"},{"product_id":"fluke-773-milliamp-process-clamp-meter","title":"Fluke 773","description":"\u003ch2\u003e\u003cstrong\u003eFluke 773 – Process Clamp Meter for mA Loop Signals\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 773\u003c\/strong\u003e is a versatile meter built for process control technicians. It allows measurement of 4-20 mA signals without breaking the loop, plus it can source mA and DC voltage for testing control I\/O or process devices. Its clamp jaw can detach for remote access in tight spaces. It includes loop power, scaled output, dual backlit display, and is rugged enough for field environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasure 4-20 mA signals via clamp without breaking the loop\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSource or simulate 4-20 mA signals for device calibration or troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides 24 V loop power to power transmitters while measuring current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasure and source DC voltage signals (e.g. 0-10 V, 1-5 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eScaled mA output matching the mA clamp reading\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimultaneous measure-and-source (mA in\/out) for valves, isolators, or control modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetachable clamp jaw usable with extension cable for tight spots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual backlit display showing mA value and percent of 4-20 mA span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHold function to freeze readings on display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in measurement spotlight for low-light areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 773\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConductor (Jaw) Diameter: up to 4.5 mm (0.177 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003emA measurement via clamp:\u003cbr\u003e - Range 0-20.99 mA, accuracy 0.2 % + 5 counts\u003cbr\u003e - Range 21.0-100.0 mA, accuracy 1 % + 5 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003emA measurement via test jacks (series): 0-24.00 mA, accuracy 0.2 % + 2 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003emA sourcing \/ simulate output: 0-24.00 mA, accuracy 0.2 % + 2 counts; maximum drive into 1,000 ohms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC voltage measure range: 0-30.00 V, accuracy 0.2 % + 2 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC voltage source (output): 0-10.00 V, accuracy 0.2 % + 2 counts; limited drive current (~2 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 °C to +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -25 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Humidity: \u0026lt; 90 % at \u0026lt; 30 °C; \u0026lt; 75 % at 30-55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize: 44 × 70 × 246 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 410 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration: 2 g random, 5-500 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock: 1 m drop (except the jaw)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP Rating: IP40\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Power: four AA 1.5 V batteries; life ~12 hours when sourcing mA into 500 ohms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWarranty: three years on electronics; one year on clamp assembly and cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTroubleshooting 4-20 mA loops in process plants without shutting systems down\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifying PLC analog inputs, control valves, transmitters while loop is powered\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasuring both current and voltage for process instruments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField work in tight or dark spaces where remote jaw and spotlight help\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 773\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSaves time by allowing live loop measurements without breaking circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCombines source, simulate, and measure functions in one tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh accuracy in lowest ranges, built rugged for industrial use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible jaw and remote configuration for tight measurement points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 773 is part of Fluke’s process clamp meter family. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534262112534,"sku":"Fluke 773","price":2286.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-773-6589157.webp?v=1780277473"},{"product_id":"fluke-376-fc-true-rms-ac-dc-clamp-meter-iflex","title":"Fluke 376 FC","description":"\u003ch2\u003e\u003cstrong\u003eFluke 376 FC – AC DC Clamp Meter with Extended Range\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 376 FC\u003c\/strong\u003e is a high-performance clamp meter for industrial and commercial electricians. It features true-RMS measurement of AC and DC current and voltage, VFD low-pass filter for non-linear loads, inrush capture, and an included flexible current probe (iFlex) for large conductors or awkward locations. It supports resistance, capacitance, frequency, has Bluetooth connectivity for remote logging and trending, and is built for safety with rugged ratings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS AC and DC measurements for voltage and current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFixed jaw current up to 1000 A AC or DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eiFlex probe extends AC current range to 2500 A for large conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVFD low-pass filter for cleaner readings under distorted waveforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInrush measurement to capture motor startup current accurately\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasure resistance, capacitance, frequency and DC millivolts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin, Max and Average recording functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBluetooth connectivity to log, trend and monitor remotely\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge backlit display with auto ranging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong safety rating for user protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 376 FC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current via Fixed Jaw: range to 999.9 A; resolution 0.1 A; accuracy ~2 % ±5 digits (10-100 Hz), ~2.5 % ±5 digits (100-500 Hz) (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current via iFlex Probe: up to 2500 A; resolution 0.1 A ≤ ~600 A, 1 A above; accuracy around 3 % ±5 digits (5-500 Hz) (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current: up to 999.9 A; resolution 0.1 A; accuracy ~2 % ±5 digits (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-376-fc?srsltid=AfmBOoodLa91uRiZ_rLTGE3FQRrAmiQdMEGhfQgy-1Zl-v2G8fxogPxm\u0026amp;utm_source=chatgpt.com\" title=\"True-RMS Clamp Meter | Fluke 376 FC AC\/DC with iFlex\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage: up to 1000 V; resolution 0.1 V (≤ 600 V), 1 V (1000 V); accuracy ~1.5 % ±5 digits (20-500 Hz) (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage: up to 1000 V; resolution 0.1 V; accuracy ~1 % ±5 digits (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency: via jaw and via iFlex; 5.0 Hz to 500.0 Hz; resolution 0.1 Hz; accuracy ~0.5 % ±5 digits (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: up to 60 kΩ; resolution varies (0.1 Ω at low range up to 10 Ω at high range) (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance: up to 1000 µF; resolution 1 µF; accuracy ~1 % ±4 digits (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Millivolts: range to 500 mV; resolution 0.1 mV (\u003ca href=\"https:\/\/www.fluke-direct.com\/product\/fluke-376-fc-trms-ac-dc-clamp-meter?utm_source=chatgpt.com\" title=\"Fluke 376 FC True RMS AC\/DC Clamp Meter with iFlex\"\u003efluke-direct.com\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJaw Opening: 34 mm (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible Probe Cable Length: ~1.8 m from head to electronics connector (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 °C to +50 °C (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 °C to +60 °C (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity (non-condensing): up to 90 % RH from 10-30 °C; decreasing at higher temps (e.g. 75 % at 30-40 °C; 45 % at 40-50 °C) (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (L × W × H): ~249 × 85 × 45 mm (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~395 g (\u003ca href=\"https:\/\/www.myflukestore.com\/product\/fluke-376-fc-trms-ac-dc-clamp-meter?utm_source=chatgpt.com\" title=\"Fluke 376 FC True RMS AC\/DC Clamp Meter with iFlex\"\u003eMy Fluke Store\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Voltage between any Terminal and Earth Ground: 1000 V (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Ratings: CAT III 1000 V and CAT IV 600 V; Pollution Degree 2 (\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/4499178.pdf?utm_source=chatgpt.com\" title=\"Fluke 376 FC True-RMS Clamp Meter with iFlex\"\u003eFarnell\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial troubleshooting where high currents and large conductors are common\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasuring in environments with variable frequency drives or distorted waveforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapturing motor startup inrush current for predictive maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote logging and trend analysis via Bluetooth for safety and efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChecking resistance, capacitance, frequency in the same tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 376 FC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines wide current and voltage ranges with high safety protections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eiFlex probe gives flexibility and reach for large cables or hard to access places\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFeatures like inrush capture and low-pass filtering ensure accuracy under challenging conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWireless logging helps document work without compromising safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 376 FC is part of Fluke’s 370-FC clamp meter series. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534287540502,"sku":"Fluke 376 FC","price":874.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-376-fc-3297885.webp?v=1780277532"},{"product_id":"fluke-754-documenting-process-calibrator-hart","title":"Fluke 754","description":"\u003ch2\u003e\u003cstrong\u003eFluke 754 – Documenting Process Calibrator-HART\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 754\u003c\/strong\u003e is a rugged handheld calibrator that combines measuring, sourcing and simulating of electrical signals, temperature sensors, pressure modules and HART smart devices in one tool. It automates calibration procedures, records results for documentation, supports fast pulsed RTDs or PLC inputs and includes built-in HART communication. Designed for calibration, maintenance and field use in demanding environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasure, source and simulate voltage, current, resistance, temperature, frequency and pressure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in HART communication for smart transmitter configuration and calibration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStores and documents calibration procedures with automatic recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoop power with selectable 26 V to power field devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHandles fast pulses down to 1 ms for RTD or PLC inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual display for viewing source and measure values simultaneously\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRechargeable Li-ion battery providing more than 8 hours of typical operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged design with IP52 rating, built for field environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 754\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Measure Range: up to 300 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Measure Range: up to 300 V, 40–500 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Source\/Simulate: up to 24 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Source Range: up to 10 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Measure\/Source Range: 0–10 kΩ depending on range selected\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Source\/Measure: 0.1 Hz to 50 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple and RTD support for multiple sensor types\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure measurement with up to 29 pressure modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData log capacity: up to one week of procedures and results\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoop Power Output: 26 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: dual channel, backlit, multilingual interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery: rechargeable Li-ion pack, 7.2 V, 4400 mAh, life \u0026gt; 8 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize: 136 × 245 × 63 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: approximately 1.2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 °C to +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -20 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Rating: IP52\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety: CAT II 300 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration of transmitters, sensors and control devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDocumentation of calibration for compliance and quality systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHART smart device configuration and testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess loop troubleshooting with source and measure in one tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField service in demanding industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 754\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines multiple calibration functions into a single rugged instrument\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSaves time with automatic documentation and stored procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in HART communication eliminates need for separate communicator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable accuracy, battery life and durability for industrial use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534305071382,"sku":"Fluke 754","price":18910.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-754-8375289.webp?v=1780276753"},{"product_id":"fluke-324-true-rms-clamp-meter-temp-capacitance","title":"Fluke 324","description":"\u003ch2\u003e\u003cstrong\u003eFluke 324 – Clamp Meter with Expanded Function for HVAC and Maintenance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 324\u003c\/strong\u003e is a rugged clamp meter for electricians and HVAC professionals. It provides true-RMS measurements for AC current (up to 400 A) and AC\/DC voltage (up to 600 V), along with resistance, continuity, temperature, and capacitance functions. It includes a backlight and data hold for field convenience, a slim jaw design, and strong safety ratings, making it suited for tough environments and a wide variety of test tasks.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS measurement for AC voltage and AC current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC current range up to 400 A through the clamp jaw\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC\/DC voltage measurement up to 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance up to 4 kΩ with continuity detection below 30 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature measurement from -10 °C to +400 °C (14 °F to 752 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance measurement from 0 to 1000 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge backlight display for use in dim conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData hold function to freeze reading on display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSoft carrying case and two-year warranty included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 324\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Range (Jaw): 40.00 A \/ 400.0 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Accuracy: 1.5 % ± 5 digits (45 Hz to 400 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC\/DC Voltage Range: up to 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Accuracy: AC 1.5 % ± 5 digits; DC 1.0 % ± 5 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: 400 Ω \/ 4000 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Accuracy: 1.0 % ± 5 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity Threshold: ≤ 30 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Range: 0-100 µF \/ 100-1000 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Range: -10 °C to +400 °C; resolution 0.1 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResponse: True-RMS for AC voltage and current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (H × W × D): 207 × 75 × 34 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Wire Diameter: 30 mm (600 MCM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~208 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Category Rating: CAT III 600 V \/ CAT IV 300 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC system diagnostics involving both electrical and temperature checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResidential and commercial electrical maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifying current and voltage on load circuits and panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance testing for components in industrial machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 324\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAdds temperature and capacitance to standard clamp meter functions, increasing versatility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS ensures accurate readings under non-linear or distorted signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust safety ratings and rugged build suitable for field and heavy-use conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 324 is part of the Fluke 320 series clamp meters. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534352683286,"sku":"Fluke 324","price":540.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-324-9048752.webp?v=1780277526"},{"product_id":"fluke-1664-fc-multifunction-installation-tester","title":"Fluke 1664 FC","description":"\u003ch2\u003e\u003cstrong\u003eFluke 1664 FC – Multifunction Installation Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 1664 FC\u003c\/strong\u003e is designed for electricians who need efficient, safe, and fully featured verification of electrical installations. It includes automatic test sequencing, an insulation pretest that prevents damage to connected appliances, support for RCD type B with smooth direct current monitoring, and wireless sharing of results via smartphone. It is robust in build, with safety and regulatory compliance for demanding field environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Pretest to detect connected appliances and stop test\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto Test sequence of seven installation tests in one connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupport for RCD type B and RDC-DD for smooth DC currents in EV charging stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoop and line impedance tests with high current loop mode for speed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProspective earth fault current and prospective short-circuit current calculation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRCD trip current and trip time tests, including ramp tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhase sequence indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge, backlit display with clear symbols and wide viewing angle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMemory for highest loop test value (Z-Max)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes zero adapter to compensate test lead and mains cord resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 1664 FC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC and DC voltage measurement range: up to 500 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage resolution: 0.1 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage accuracy (45-66 Hz): 0.8% + 3 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput impedance: 360 kΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOverload protection: 660 V rms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity testing (resistive loads only, autoranging): ranges of 20 Ω \/ 200 Ω \/ 2000 Ω; resolution 0.01 Ω \/ 0.1 Ω \/ 1 Ω; open circuit voltage \u0026gt; 4 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation resistance test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation resistance ranges and resolutions: up to 1000 MΩ in higher test voltages; resolutions down to 0.01 MΩ depending on voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoop and line impedance range: 10 Ω (high current milliohm mode), 20 Ω, 200 Ω, 2000 Ω; resolution down to 0.001 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProspective earth fault current and prospective short-circuit current: up to 1000 A \/ 10 kA (50 kA in some cases) with resolution 1 A \/ 0.1 kA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRCD types tested: AC, type A, type B, G, S; includes test currents and ramp modes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhase sequence indicator: for mains voltages between ~100-500 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (L × W × H): 10 × 25 × 12.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight (with batteries): ~1.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower supply: 6 × AA type batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection rating: IP-40\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety category: CAT III 500 V \/ CAT IV 300 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandards compliance: EN\/IEC 61010-1, EN\/IEC 61010-2-034; Performance per EN61557-1 through EN61557-7 and EN61557-10\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation verification for domestic, commercial and industrial settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting EV charging stations and DC sensitive RCDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCertifying wiring safety including loop impedance, insulation, polarity, RCD trip parameters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField work where documenting and sharing test results matters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 1664 FC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAuto Test sequence saves time and reduces risk of missing tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Pretest prevents accidental damage to connected devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBroad support for RCD type B and smooth DC modes for modern installation needs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWireless result sharing adds traceability and collaboration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1664 FC is part of Fluke’s 1660 series installation testers. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534366249238,"sku":"Fluke 1664 FC","price":5980.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-1664-fc-4558997.webp?v=1780276745"},{"product_id":"fluke-287-true-rms-electronics-logging-multimeter","title":"Fluke 287","description":"\u003ch2\u003e\u003cstrong\u003eFluke 287 – Logging Multimeter with TrendCapture\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 287\u003c\/strong\u003e is a high-precision electronics multimeter designed for professionals who need to monitor, log and troubleshoot complex electrical systems. It offers True-RMS measurements, a real-time clock for timestamped logging, a large display with white backlight to show multiple values at once, and the TrendCapture feature which allows graphs of logged data to be reviewed on the meter itself. Ideal for design engineers, plant maintenance, R\u0026amp;D and systems requiring detailed diagnostics and long-term monitoring.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS AC and DC voltage and current for accurate readings under complex or non-linear loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge 50,000-count ¼ VGA display with white backlight; allows multiple measurement parameters on screen simultaneously\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrendCapture on-board graph display of logged readings without needing a PC; up to 15,000 recorded events\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePeak capture for transients down to 250 µs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature measurement (-200 °C to +1350 °C) excluding probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapability to log for long periods; battery life ~100 hours under normal use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative mode to subtract lead offset, useful in low ohms or capacitance tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 287\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Ranges: 50.000 mV; 500.00 mV; 5.0000 V; 50.000 V; 500.00 V; 1000.0 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Accuracy: ±0.025 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Ranges: same as DC ranges; AC bandwidth to 100 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Accuracy: ±0.4 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current Ranges: 500.00 µA; 5000.0 µA; 50.000 mA; 400.00 mA; 5.0000 A; 10.000 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current Accuracy: ±0.05 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Ranges: same as DC; True-RMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Accuracy: ±0.6 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: up to 500.0 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Range: up to 100 mF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Range: up to ~1 MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Range: -200 °C to +1350 °C (with probe)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Input Voltage: 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery: 6 AA alkaline cells\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: approximately 100 hours typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -20 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (H × W × D): 22.2 × 10.2 × 6.0 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~870 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Rating: CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring electrical circuits for design, R\u0026amp;D and maintenance troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapturing intermittent faults or drift in voltage or current over time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTest and service of power supplies, electronic control systems, industrial automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal, resistance or capacitance characterization under live conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 287\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines high accuracy, extensive range and long logging memory\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePowerful screen and display features help identify issues right on the meter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS ensures correct readings in demanding electrical environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged build, long battery life, designed for professional use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 287 is part of Fluke’s logging multimeter family. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534374670614,"sku":"Fluke 287","price":1350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-287-1799488.webp?v=1780276816"},{"product_id":"fluke-725-multifunction-process-calibrator","title":"Fluke 725","description":"\u003ch2\u003e\u003cstrong\u003eFluke 725 – Multifunction Process Calibrator\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 725\u003c\/strong\u003e is a versatile field calibrator designed to source, measure and simulate key process signals for maintenance, testing and calibration. It handles current, voltage, temperature sensors, resistance, frequency and pressure (with optional modules). It includes built-in 24 V loop power so you can power transmitters while measuring output. The device is rugged, compact, has simple controls and a backlit display for ease of use in tough environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSource and measure DC current (mA), DC voltage, resistance, frequency, temperature, pressure modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in 24 V loop power supply for powering transmitters during tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimultaneous measure and source capability so input and output can be seen at same time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupport for thermocouples and RTDs for both measure and source functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSource\/simulate pressure via compatible pressure modules for valve or I\/P tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto-step and auto-ramp functions for fast linearity or span tests\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStore and recall frequently used calibration setup configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBacklit display for visibility in low-light field conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged, easy-to-carry design with simple user interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 725\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current (source \/ measure): up to 24.000 mA, accuracy ~0.02 % + 2 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage (measure \/ source): ranges include 100.00 mV, up to ~30.000 V; accuracy ~0.02 % + 2 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance ranges: from low ohm (~0 Ω) up to ~3200 Ω; accuracy varies with range (~0.1 to 1.0 Ω depending on wiring method)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency range: up to ~10.00 kHz (or higher in some modes like CPM), resolution ~0.1 unit; accuracy ~0.05 % + 1 count\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple support: many types (J, K, T, E, etc.), with resolution 0.1 °C or better; accuracy depends on type and range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRTD support: standard types (Pt100, Ni120, etc.), measure and source; accuracy typically ~0.2-0.5 °C depending on type and range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure support: via optional modules; accuracy per module (e.g. ~0.025 % of range for some modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoop power output: 24 V, capable of powering transmitters while measuring current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExcitation current for resistance\/RTD sources: varies with range; low ranges may allow few mA, higher ranges less\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: -10 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage temperature: approximately -20 °C to +71 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower supply: four AA batteries; typical battery life depends on usage but field-rated for many hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (H × W × D): ~130 × 236 × 61 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~0.65 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCalibrating temperature and pressure transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifying process signal outputs in mA, volts or frequency in control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlow meter and I\/P valve testing with pressure modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField maintenance and troubleshooting where test source and measure are needed simultaneously\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerforming linearity and span checks with auto-step or auto-ramp features\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 725\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines many calibration functions into one unit to reduce tool load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimultaneous source\/measure and loop power save time and simplify field calibration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged build and intuitive interface make it ideal for harsh environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional pressure module support expands functionality for process instrumentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 725 is part of Fluke’s 720-series process calibrators. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534390858006,"sku":"Fluke 725","price":5980.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-725-4533963.webp?v=1780276459"},{"product_id":"fluke-381-remote-display-true-rms-clamp-meter-iflex","title":"Fluke 381","description":"\u003ch2\u003e\u003cstrong\u003eFluke 381 – Remote Display True-RMS AC DC Clamp Meter with iFlex\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 381\u003c\/strong\u003e lets one technician make measurements around a conductor, remove the display and monitor readings from a distance. It includes a flexible current probe (iFlex) to extend the AC current range, and supports AC\/DC voltage and current, inrush capture, resistance, frequency functions. Designed for safety and flexibility in noisy or awkward environments with rugged build and strong performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRemovable magnetic display that can be placed 30 feet away for safer, more flexible readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eiFlex flexible current probe included to extend AC current measurement up to 2500 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS AC and DC voltage and current for accurate results under non-linear loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated low-pass filter for stable readings in noisy electrical environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInrush recording to capture motor startup current exactly as protection sees it\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin, max, average record functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance measurement with continuity detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC\/DC voltage to 1000 V through fixed jaw and leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency measurement up to 500 Hz via jaw or iFlex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety rating CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 381\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current via Jaw: up to 999.9 A; resolution 0.1 A; accuracy 2 % ± 5 digits (10-100 Hz), 5 % ± 5 digits (100-500 Hz) (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current via iFlex Probe: up to 2500 A AC (45-500 Hz); resolution 0.1 A \/ 1 A depending on current; accuracy 3 % ± 5 digits (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current: range up to 999.9 A; resolution 0.1 A; accuracy ~2 % ± 5 digits (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage: up to 1000 V; resolution 0.1 V \/ 1 V; accuracy ~1.5 % ± 5 digits (20-500 Hz) (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage: up to 1000 V; resolution 0.1 V \/ 1 V; accuracy ~1 % ± 5 digits (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency (via jaw): 5.0 Hz to 500.0 Hz; resolution 0.1 Hz; accuracy 0.5 % ± 5 digits (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency (via iFlex): 5.0 Hz to 500.0 Hz; resolution 0.1 Hz; accuracy 0.5 % ± 5 digits with trigger thresholds depending on current level (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance: up to 60,000 Ω; resolution 0.1 Ω \/ 1 Ω \/ 10 Ω depending on range; accuracy ~1 % ± 5 digits (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJaw Opening: 34 mm (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible Probe Diameter: ~7.5 mm; cable length from head to electronics ~1.8 m (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (L × W × H): 277 × 88 × 43 mm (remote display unit ~55 mm) (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~350 g (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 °C to +50 °C (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 °C to +60 °C (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Humidity: non-condensing; up to 90 % RH at 10-30 °C, lower % at higher temps (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAltitude (Operating): up to 2000 m; Storage Altitude: up to 12,000 m (\u003ca href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/clamp-meters\/fluke-381?srsltid=AfmBOooGcK7HFEuSWNqRghFE34ShfWN3kHbz0H9uEbYOjNnL1tAs9mtN\u0026amp;utm_source=chatgpt.com\" title=\"Fluke 381 Remote Display True RMS AC\/DC Clamp Meter ...\"\u003eFluke\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasuring current in large conductors or cables where size or layout makes fixed jaw difficult\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote monitoring of panel circuits or controls while working under protective equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapturing inrush current events in motors, HVAC equipment or machine startups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField verification of voltage, resistance, frequency in industrial or commercial systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 381\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRemote display adds safety and convenience\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVery high current range with iFlex for hard-to-reach or overloaded conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue RMS and filters help in noisy or non-linear electrical environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged build with strong safety ratings for heavy use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 381 is part of Fluke’s remote display clamp meter family. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534399017238,"sku":"Fluke 381","price":1350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-381-9837980.webp?v=1780278134"},{"product_id":"fluke-1503-insulation-resistance-tester","title":"Fluke 1503","description":"\u003ch2\u003e\u003cstrong\u003eFluke 1503 – Compact Insulation Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 1503\u003c\/strong\u003e is a rugged and compact insulation resistance tester suited for industrial, commercial and maintenance use. It supports high voltage insulation tests at 500 V and 1000 V, live-circuit detection to prevent unsafe testing, auto discharge for capacitive loads, and remote probe capability for hard-to-reach areas. It meets strong safety ratings and is designed for durability and reliability in harsh environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation test voltages of 500 V and 1000 V for measuring insulation resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation resistance range from 0.01 MΩ up to 2000 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLive circuit detection inhibits test if terminal voltage above ~30 V is present\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto discharge of capacitive voltage for safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote probe included for testing in hard or repetitive test locations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOverload protection up to 600 V AC or DC on any terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge backlit display for easy reading in low light\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery powered (four AA batteries) for field portability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged design: vibration, shock, IP40 rated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 1503\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Resistance Range: 0.01 MΩ to 2000 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTest Voltages: 500 V DC, 1000 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Test Voltage Accuracy: +20 % \/ −0 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort-Circuit Current (at insulation test): ~1 mA nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Capacitive Load: operates properly up to ~1 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Terminal Voltage Rated: 600 V AC rms or DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: −20 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: −40 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity:\u003cbr\u003e - 0 to 95% at 10-30 °C\u003cbr\u003e - 0 to 75% at 30-40 °C\u003cbr\u003e - 0 to 40% at 40-55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (H × W × D): approximately 5.0 × 10.0 × 20.3 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~550 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eChecking insulation integrity on motors, cables, switchgear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreventive maintenance to detect worn or failing insulation early\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting insulation after installation or repairs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField use where safety features like live-circuit detection and auto-discharge are important\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 1503\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHigh test voltages with wide resistance range for many insulation challenges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong safety protections to protect user and equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote probe and rugged build make it efficient in field work\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1503 is part of Fluke’s insulation tester family. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534419071254,"sku":"Fluke 1503","price":540.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-1503-2677376.webp?v=1780278012"},{"product_id":"fluke-971-temperature-humidity-meter","title":"Fluke 971","description":"\u003ch2\u003e\u003cstrong\u003eFluke 971 – Compact Indoor Air Quality Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 971\u003c\/strong\u003e is a handheld meter for monitoring indoor environment conditions. It displays temperature and relative humidity simultaneously, supports dew point and wet bulb readings, and stores up to 99 readings. Designed for HVAC technicians, facility maintenance and indoor air quality specialists. Lightweight, rugged with a protective holster, and suited for job-site use.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDual backlit display showing temperature and humidity at once\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures dew point and wet bulb temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStores up to 99 records for temperature and humidity readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin, Max, Average data hold functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuick-response capacitance sensor with protective cover\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact ergonomic design with belt clip and protective holster\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow battery indicator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight (~ 190 g) for easy carrying\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 971\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Range: −20 °C to +60 °C (−4 °F to +140 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Accuracy: ±0.5 °C for 0 °C to 45 °C; ±1.0 °C outside that range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Resolution: 0.1 °C \/ 0.1 °F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity Range: 5 % to 95 % RH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity Accuracy: ±2.5 % RH for 10 %-90 % RH at 23 °C; ±5.0 % RH outside that span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity Resolution: 0.1 % RH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResponse Time (for humidity): 60 seconds for 90 % of full scale with 1 m\/s air flow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Update Rate: 500 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Conditions: temperature −20 °C to +60 °C; RH up to 95 % at moderate temperatures; storage −20 °C to +60 °C with battery removed under \u0026lt; 80 % RH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~190 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: ~194 × 60 × 34 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower: 4 AAA alkaline batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: up to ~200 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring indoor air quality (IAQ) in buildings and facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC system diagnostics and set-ups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifying environmental conditions to prevent mold or comfort issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData center monitoring, clean rooms or libraries where humidity control matters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 971\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDual display offers simultaneous humidity and temperature for quick readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes dew point and wet bulb functionality for more effective environmental assessment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData logging of 99 points helps tracking over time without extra tools\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 971 is part of Fluke’s indoor air quality tools. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534443974934,"sku":"Fluke 971","price":784.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-971-4429327.webp?v=1780276865"},{"product_id":"fluke-114-true-rms-electrical-multimeter","title":"Fluke 114","description":"\u003ch2\u003e\u003cstrong\u003eFluke 114 – Compact Multimeter for Go\/No-Go Testing\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 114\u003c\/strong\u003e is a compact True-RMS multimeter designed for everyday electrical troubleshooting and go\/no-go testing. It comes with AutoVolt which switches automatically between AC and DC voltage, a Low-Z mode to avoid false readings from ghost voltages, and a large LED backlight for visibility in poor lighting. It is safety rated for CAT III 600 V, and includes features like resistance, continuity, and Min\/Max\/Average recording of fluctuations. It fits easily into one hand for field use.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAutoVolt automatic AC\/DC voltage selection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-Z mode to help prevent false readings from ghost or phantom voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhite LED backlight for visibility in low light conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures resistance and continuity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecords Min, Max and Average readings to track signal fluctuations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact ergonomic design suitable for one-hand operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes holster with probe holders for safe storage of test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCAT III 600 V safety rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 114\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Voltage Between Any Terminal and Earth Ground: 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Rating: CAT III 600 V, Pollution Degree 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: 6000 counts, updates 4 times per second\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBar Graph: 33 segments, updates 32 times per second\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: −10 °C to +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: −40 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery: 9 V alkaline battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: approximately 400 hours without backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Millivolts: up to 600.0 mV; resolution 0.1 mV; accuracy ±0.5% + 2 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage: ranges 6.000 V \/ 60.00 V \/ 600.0 V; accuracy ±0.5% + 2 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage (True-RMS): up to 600.0 V; accuracy 1.0% + 3 counts (45-500 Hz), 2.0% + 3 counts (500 Hz-1 kHz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity: range up to 600 Ω; beeper on under ~20 Ω; detects opens or shorts ≥500 µs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance: ranges 600.0 Ω to 40.00 MΩ; accuracy 0.9% + 1 count on lower ranges, 5% + 2 on highest range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRoutine electrical troubleshooting in residential, commercial or industrial settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChecking voltage safely, avoiding ghost readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting continuity and resistance in wiring and components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapturing variations of voltage for diagnosing intermittent or fluctuating circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 114\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS accuracy ensures reliable readings even with distorted signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutoVolt and Low-Z features improve safety and reduce misdiagnosis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong battery life and rugged build for reliable field performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact design allows easy single-handed operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 114 is part of Fluke’s 110-series electrical multimeters. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534450430230,"sku":"Fluke 114","price":380.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-114-2923455.webp?v=1780276938"},{"product_id":"fluke-771-milliamp-process-clamp-meter","title":"Fluke 771","description":"\u003ch2\u003e\u003cstrong\u003eFluke 771 – Milliamp Process Clamp Meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 771\u003c\/strong\u003e is a clamp meter designed specifically for process control environments. It lets you measure milliamp current loops (4-20 mA and up to 100 mA) without breaking the loop, so you avoid interrupting critical systems. It has a remote detachable clamp for tight or awkward locations, a dual backlit display that shows mA and the percent of span of a 4-20 mA loop, and a built-in spotlight for working in low-light enclosures. It helps save time and improve safety for automation, PLC and instrumentation work.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasure 4-20 mA signals without breaking the loop\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh accuracy of 0.20 % + 2 counts in lower range (0-20.99 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution of 0.01 mA in the lower range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtended range up to 100.0 mA (99.9 mA) with reduced accuracy (1 % + 5 counts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetachable remote clamp head with extension cable for tight areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual backlit display showing measured mA and percent of 4-20 mA span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHold function to freeze readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated LED spotlight to illuminate wires in dark locations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSoft carrying case included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrusted 3-year warranty for electronics; 1-year on clamp\/cable assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 771\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Ranges (via clamp):\u003cbr\u003e - 0.00 to 20.99 mA, resolution 0.01 mA, accuracy 0.20 % + 2 counts\u003cbr\u003e - 21.0 to 100.0 mA, resolution 0.10 mA, accuracy 1 % + 5 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiameter of measurable conductor: up to 4.5 mm (0.177 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 °C to +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -25 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Humidity: \u0026lt; 90 % at \u0026lt; 30 °C; \u0026lt; 75 % at 30-55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Altitude: 0 to 2000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIngress Protection Rating: IP 40\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize (H × W × Depth): 59 × 38 × 212 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~260 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration: Random 2 g, 5-500 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock: 1 m drop (except the clamp jaw)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectromagnetic Compatibility: Meets EN 61326-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Coefficient: 0.01 % per °C outside 18-28 °C range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: 2 × AA 1.5 V alkaline batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: ~40 hours typical use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWarranty: 3 years on electronics; 1 year on cable\/clamp assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTroubleshooting 4-20 mA loops in process plants without interrupting control circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChecking analog I\/O status in PLCs and instrumentation without breaking loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifying old systems with 10-50 mA ranges using the 99.9 mA mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField work in tight or recessed areas using the detachable clamp and spotlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 771\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSaves downtime by allowing live loop measurements without circuit interruption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh resolution and accuracy for precise process control diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote clamp and clamp cable make it safer and more flexible in challenging spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust design, safety protections and excellent warranty support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 771 is part of Fluke’s process clamp meter family. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534457737494,"sku":"Fluke 771","price":1970.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-771-9887985.webp?v=1780277165"},{"product_id":"fluke-107-pocket-digital-multimeter","title":"Fluke 107","description":"\u003ch2\u003e\u003cstrong\u003eFluke 107 – Palm-Sized Digital Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 107\u003c\/strong\u003e is a compact, lightweight, and reliable multimeter designed for essential electrical testing. Despite its small size, it provides all core functions needed for everyday troubleshooting, including AC and DC voltage and current, resistance, capacitance, diode test, frequency, and duty cycle. With CAT III 600 V safety rating, rugged build, and a backlit display, it is a trusted pocket tool for professionals.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures AC and DC voltage up to 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures AC and DC current up to 10 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance measurement with continuity detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance measurement for electronic and motor testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency and duty cycle measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiode test function\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData hold and backlit display for improved usability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact, portable, and lightweight design (~200 g)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCAT III 600 V safety rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 107\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Range: 6 V, 60 V, 600 V; accuracy ±0.5% + 3 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Range: 6 V, 60 V, 600 V; accuracy ±1.0% + 3 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current Range: 4.000 A, 10.00 A; accuracy ±1.5% + 3 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Range: 4.000 A, 10.00 A; accuracy ±1.5% + 3 counts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance: 400.0 Ω to 40.00 MΩ, resolution by range; accuracy ±0.5% to ±1.5%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance: 50.00 nF to 1000 μF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency: 10 Hz to 100 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDuty Cycle: 1% to 99%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiode Test Range: up to 2.000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: LCD, 6000 counts, 3 updates per second\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 °C to +40 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: −30 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: 2 AAA alkaline batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: up to 200 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 142 × 69 × 28 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~200 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Rating: CAT III 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEveryday troubleshooting in residential and commercial wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifying circuits, fuses, and components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuick field diagnostics where portability is essential\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackup tool for electricians and electronics technicians\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 107\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCompact and pocket-sized yet full of essential test functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable accuracy with True-RMS measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged safety design for professional use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEasy to carry and use in tight spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 107 is part of Fluke’s pocket digital multimeter family. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534459408662,"sku":"Fluke 107","price":290.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-107-8849545.webp?v=1780276578"},{"product_id":"fluke-t6-1000-pro-fieldsense-electrical-tester","title":"Fluke T6-1000 PRO","description":"\u003ch2\u003e\u003cstrong\u003eFluke T6-1000 PRO – Advanced Non-Contact Electrical Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke T6-1000 PRO\u003c\/strong\u003e is an advanced electrical tester that measures voltage, current, and frequency without making direct contact with live conductors. Its FieldSense technology allows simultaneous voltage and current display through the open fork, while Visual Continuity changes the screen color for fast feedback. It is rugged, accurate, and designed for professionals who need safe and quick diagnostics in the field.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFieldSense technology for non-contact AC voltage, current, and frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimultaneous display of voltage and current readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVisual Continuity feature with green screen for continuity detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS for accurate results in noisy or nonlinear systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOpen fork accommodates conductors up to AWG 4\/0 (17.8 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBacklit display and Hold function for easy visibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety rated CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: T6-1000 PRO\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage with FieldSense: 1 V to 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage (with leads): 1 V to 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current with FieldSense: 0.1 A to 200 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency (FieldSense): 45 Hz to 66 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance: 1 Ω to 100 kΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJaw Opening: 17.8 mm (0.7 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: 9999-count backlit LCD\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: 2 × AA alkaline batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: up to 360 hours typical use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: −10 °C to +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: −30 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Altitude: up to 2000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Altitude: up to 10,000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: up to 90% RH at ≤30 °C, decreasing with higher temps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 61 × 43 × 259 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~350 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Rating: CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTroubleshooting in electrical panels and control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-contact measurement in industrial and commercial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast verification of current draw and voltage on motors and pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField maintenance where safety and speed are critical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke T6-1000 PRO\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFieldSense technology reduces the need for direct contact with live wires\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS accuracy ensures reliable readings even with distorted signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge open fork supports measurements on large conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged design with excellent safety ratings for professional use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke T6-1000 PRO is part of Fluke’s FieldSense tester family. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534464586006,"sku":"Fluke T6-1000 PRO","price":556.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-t6-1000-pro-3563574.webp?v=1780278018"},{"product_id":"fluke-1736-three-phase-power-quality-logger","title":"Fluke 1736","description":"\u003ch2\u003e\u003cstrong\u003eFluke 1736 – Three-Phase Power Quality Logger\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 1736\u003c\/strong\u003e is a robust three-phase power quality logger built to monitor energy usage and the health of electrical systems. It records voltage, current, power, harmonics and many other power quality parameters. It captures events like dips, swells and inrush currents, and can be powered directly from the measured circuit. Designed for long-term logging, it offers flexibility, accuracy and advanced diagnostics for industrial, commercial and utility applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThree-phase plus neutral inputs to log voltage and current on all phases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible current probe options (e.g. 1500 A) to suit large conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatically records many power quality parameters (voltage, current, harmonics, THD, energy, power factor etc.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCaptures events: dips, swells, interruptions and inrush current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePowered directly from the measurement circuit or from external supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUser selectable logging and averaging intervals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time on-device display of key metrics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWorks with software for data analysis and reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety rated for high voltage environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 1736\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Input Range: up to 1000 V RMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Accuracy: ±(0.2 % + 0.01 %) at reference conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Range: 42.5 Hz to 69 Hz; resolution 0.01 Hz; accuracy ±0.1 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Range (with 1500 A flexible probe): 1 A to 1500 A AC; resolution 0.1 A; accuracy ±(1 % + 0.02 %)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHarmonics: Measures 2nd through 50th harmonics of voltage and current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTHD (Total Harmonic Distortion): voltage and current THD measurement included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnbalance: up to 100 %; resolution 0.1 %; accuracy ±0.2 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Measurements: active power, reactive power, apparent power, power factor, displacement power factor, energy (active and reactive)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuxiliary Input: ±10 V DC range; resolution 0.1 mV; accuracy ±(0.2 % + 0.02 %)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Impedance on Voltage Channels: 10 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBandwidth: ~42.5 Hz to ~3.5 kHz (-3 dB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply Options: Direct from measurement circuit (100-500 V) or external power cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: up to 50 VA (lower when externally powered)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: typical range around 0 °C to +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~1.1 kg instrument; power supply adds additional weight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnergy consumption studies and cost allocation in industrial and commercial plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring power quality to identify system disturbances (voltage dips, swells, inrush)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifying harmonic compliance and assessing impact of non-linear loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreventive maintenance and troubleshooting of electrical distribution systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRegulatory or warranty compliance; documenting energy usage and power quality\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 1736\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines energy logging and extensive power quality analysis in one tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccurate measurements even under distorted or complex load conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide current probe options allow use on large cables and high current feeders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong-term logging with robust event capture helps uncover intermittent issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1736 is part of Fluke’s power quality logger series. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534474121494,"sku":"Fluke 1736","price":11600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-1736-3762785.webp?v=1780277000"},{"product_id":"fluke-101-basic-digital-multimeter","title":"Fluke 101","description":"\u003ch2\u003e\u003cstrong\u003eFluke 101 – Basic Digital Multimeter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 101\u003c\/strong\u003e is a compact and rugged digital multimeter designed for everyday electrical testing. It delivers reliable AC and DC voltage measurements up to 600 V, along with resistance, capacitance, frequency, duty cycle, continuity and diode tests. Lightweight and portable, it is ideal for professionals who need a simple yet accurate tool.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBasic DC accuracy of 0.5 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCAT III 600 V safety rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiode and continuity test with buzzer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSmall, lightweight design for one-handed use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged, durable build for field work\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto shutdown to extend battery life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRuns on two AAA batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 101\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Range: up to 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Range: up to 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: 400 Ω to 40 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Range: 50 nF to 1000 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Range: 10 Hz to 100 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDuty Cycle: 0.1 % to 99.9 %\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity: audible buzzer for quick checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiode Test: included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: 6000-count LCD, 3 updates per second\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: 2 × AAA batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: up to 200 hours typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 130 × 65 × 27 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~160 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 °C to +40 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: −30 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: up to 90 % RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Rating: CAT III 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBasic electrical checks in residential and commercial systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance, capacitance and frequency testing in light circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiode and continuity verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePortable troubleshooting tool for electricians and technicians\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 101\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePocket-sized yet accurate and safe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEssential functions without unnecessary complexity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged construction ensures long service life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAffordable entry-level multimeter with Fluke reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 101 is part of Fluke’s basic digital multimeter line. Available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534486704406,"sku":"Fluke 101","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-101-1367714.webp?v=1780279027"},{"product_id":"fluke-787-processmeter-multimeter-loop-calibrator","title":"Fluke 787","description":"\u003ch2\u003e\u003cstrong\u003eFluke 787 – Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 787 ProcessMeter\u003c\/strong\u003e is a robust handheld tool that combines the functionality of a digital multimeter with a loop calibrator. It enables technicians to measure, source, and simulate process current while performing standard electrical tests. Designed for plant maintenance and instrumentation tasks, the 787 reduces the need to carry multiple tools, saving time in the field.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines digital multimeter and loop calibrator in one device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSources and simulates 0–20 mA or 4–20 mA signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrive capability up to 500 Ω at 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures AC\/DC voltage up to 1000 V and current up to 1 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance measurement up to 40 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency measurement up to 20 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity and diode test functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin\/Max\/Average\/Hold modes for data logging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge dual display with backlight and percent-of-scale mA reading\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged construction for demanding industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: Fluke 787\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Output Range: 0–20 mA or 4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Drive Capability: 500 Ω at 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Measurement Range: up to 1 A AC\/DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Measurement Range: up to 1000 V AC\/DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: up to 40 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Measurement: up to 19.999 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy (DC Voltage): ±0.1% of reading + 1 digit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy (mA Source): ±0.05% of span\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: Dual digital with backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Rating: CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –20 °C to +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: –40 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: up to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: 9 V battery, externally accessible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 32 × 87 × 187 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: approx. 369 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Rating: IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration and simulation of process loops in industrial automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintenance of transmitters, actuators, and sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTroubleshooting 4–20 mA control loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical testing with a single versatile instrument\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 787\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines two essential tools into one compact device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSaves time by allowing simultaneous mA and electrical measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh accuracy for both calibration and troubleshooting tasks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged and reliable design for industrial field use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 787 ProcessMeter is available in stock and ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50534498304278,"sku":"Fluke 787","price":2700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-787-4421202.webp?v=1780276579"},{"product_id":"fluke-t6-600-field-sense-electrical-tester","title":"Fluke T6-600","description":"\u003ch2\u003e\u003cstrong\u003eFluke T6-600 – Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke T6-600\u003c\/strong\u003e is a versatile open-jaw electrical tester using FieldSense technology so users can measure AC voltage and current without needing to touch live conductors with test leads. This saves time, increases safety, and allows fast diagnostics of power circuits. It also handles traditional measurements (voltage, resistance) with test leads when needed.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFieldSense technology: measure AC voltage \u0026amp; current without test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOpen jaw (fork) design for AC measurements without touching live metal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue RMS AC voltage and current readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC voltage, resistance measurement using test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge jaw opening (17.8 mm) to accommodate large conductors (up to ~AWG 4\/0)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBacklit display and “HOLD” function for easier reading\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight, portable design for field work\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong battery life on standard AA batteries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke T6-600\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage (FieldSense, no leads): up to 600 V AC; resolution 1 V; accuracy ±(3% + 3 counts) at 45-66 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current (FieldSense, no leads): up to 200 A AC; resolution 0.1 A; accuracy ±(3% + 3 counts) at 45-66 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage (with test leads): up to 600 V DC; resolution 1 V; accuracy ±(1% + 2 counts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance (with test leads): up to 2,000 Ω; resolution 1 Ω; accuracy ±(1% + 2 counts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Category: 600 V CAT III\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJaw Opening: 17.8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -30 … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAltitude: Operation to 2,000 m; storage to 10,000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 0-90 % up to 30 °C; reducing as temperature rises\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Type \u0026amp; Life: 2 × AA; ~360 h continuous; ~200 h using FieldSense mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: ~61.1 × 259.3 × 43.8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~0.35 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQuickly verifying voltage and current in electrical panels without removing safety shields\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting large conductors where traditional probes don’t reach\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnosing AC power supplies and circuits in industrial setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral field service work: electrical contractors, maintenance, troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke T6-600\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOffers safe non-contact AC measurement via open jaw, reducing risk and effort\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports both FieldSense and traditional lead-based measurements for flexibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue RMS makes it better for distorted waveforms or non-linear loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong battery life and rugged build make it reliable in harsh field environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke T6-600 is in stock and available worldwide. Ships immediately.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50536149909782,"sku":"T6-600","price":380.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-t6-600-7213824.webp?v=1780279224"},{"product_id":"fluke-113-utility-multimeter-cat-iv-600v","title":"Fluke 113","description":"\u003ch2\u003e\u003cstrong\u003eFluke 113 – Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 113 Utility Multimeter\u003c\/strong\u003e is a rugged, easy-to-use instrument designed for basic electrical testing. It offers low-impedance voltage detection (VCHEK) to avoid ghost voltages, measures both AC\/DC voltage with True-RMS, tests continuity and diodes, and includes a large, backlit display and built-in holster with probe holders—perfect for field technicians, electricians, or general maintenance tasks.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eVCHEK™ low-impedance (LoZ) function for detecting voltage or continuity in same dial position\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS AC voltage for accurate measurements on non-linear loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge backlit display for visibility in low light\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiode test, continuity test with audible beeper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin\/Max recording of fluctuating signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto and manual ranging modes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTriple safety category rating: CAT IV 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegral holster with probe storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: Fluke 113\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC\/DC Voltage Ranges (VCHEK): 6.000 V \/ 60.00 V \/ 600.0 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution (Voltage): 0.001 V \/ 0.01 V \/ 0.1 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC\/DC Voltage Accuracy:\u003cbr\u003e  • DC \u0026amp; 45-500 Hz: ±(2.0 % + 3 counts)\u003cbr\u003e  • 500 Hz - 1 kHz: ±(4.0 % + 3 counts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiode Test Range: 2.000 V, Resolution 0.001 V, Accuracy ~2.0 % + 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity: Beeper threshold \u0026lt; 20 Ω, off \u0026gt; 250 Ω, detect opens\/shorts ≥ 500 µs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Ranges: 600 Ω, 6 kΩ, 60 kΩ; Resolution varies (0.1 Ω to 0.01 kΩ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Accuracy: ~0.9 % + 1 to +2 counts depending on range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Ranges: 1,000 nF; 10 µF; 100 µF; 9,999 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Accuracy: ~1.9 % + 2 counts (higher error on largest range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMax Voltage Rating: 600 V between any terminal and earth ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: 3¾ digits, 6,000 counts, refresh ~4 readings\/sec\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temp: -10 … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temp: -40 … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery: 9 V alkaline (installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: ~300 hours typical (without backlight)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: ~167.1 × 85.1 × 46.0 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~404 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Standards: IEC\/EN 61010-1, Pollution Degree 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAltitude (Use): up to ~2,000 m; Storage up to ~10,000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eUtility and field inspection work where safety and accuracy matter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnosing electrical circuits in residential or commercial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetecting ghost voltages, verifying voltage presence or absence safely\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBasic component testing (diodes, resistors) and fluctuations in signal monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 113\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines essential meter features with safety and durability for everyday use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoZ-mode (VCHEK) helps avoid false voltage readings, increasing safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS ensures better accuracy with complex waveforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong battery life and robust build make it reliable in the field\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 113 Utility Multimeter is available now. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50536263319830,"sku":"Fluke 113","price":308.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-113-4688529.webp?v=1780277477"},{"product_id":"fluke-726-precision-multifunction-process-calibrator","title":"Fluke 726","description":"\u003ch2\u003e\u003cstrong\u003eFluke 726 – Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 726\u003c\/strong\u003e is a versatile multifunction calibrator designed for process technicians. It can measure and source many signals (voltage, current, RTDs, thermocouples, frequency, resistance, and pressure modules) enabling calibration of sensors, transmitters, and valves all in one tool. It also features loop powering, memory storage for calibration results, and built-in functions to speed up calibration tasks.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasure \u0026amp; source: volts, mA, mV, resistance, frequency, RTDs, thermocouples\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports Fluke 700P pressure modules for pressure measurement\/sourcing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in 24 V loop power supply (for powering transmitters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto-step and auto-ramp functions to speed calibration sequences\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStores up to 8 calibration results internally for later review\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalculates transmitter error % and supports pressure switch testing (set\/reset\/deadband)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCustom RTD constants for non-standard RTD probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual-channel simultaneous measure\/source capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: Fluke 726\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage (measure): up to 30.000 V, accuracy 0.01% + 2 mV (upper display)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage (source): up to 20.000 V, same accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-mV range: -10.00 … +75.00 mV via TC connector, accuracy ~0.025% + 1 count\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent (measure\/source): 0.000 … 24.000 mA DC, accuracy 0.01% + 2 µA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance (measure\/source): 0.00 … 4000.0 Ω, accuracy 0.015% + small offset depending on range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency measure\/source: ranges from ~2 CPM \/ Hz up to ~15 kHz, with accuracy around 0.05% + small count error\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoop power supply: 24 V DC, short-circuit protected\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple\/RTD accuracy: varies by type (PT100, J, K, etc.), resolution to 0.01 °C in many cases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 … +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -20 … +71 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: ~200 × 96 × 47 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~650 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower: 4 × AA alkaline batteries, accessible without breaking calibration seal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety \/ Approvals: EN 61010-1 etc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration of process transmitters, sensors, RTDs, thermocouples, pressure modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField and plant maintenance where multiple signal types are involved\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuality control and lab calibration work needing accuracy and flexibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSituations that require field-powering of loops and error calculation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 726\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines many calibration tools into one compact unit, saving cost and carry-weight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh accuracy across many signal types reduces error and improves confidence\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMemory storage and automation (ramp\/step) speed up calibration jobs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in loop supply and pressure module support make it very versatile\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 726 Precision Multifunction Process Calibrator is available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50536270758166,"sku":"Fluke 726","price":7910.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-726-8220765.webp?v=1780276278"},{"product_id":"fluke-tl175-twistguard-test-leads","title":"Fluke TL175","description":"\u003ch2\u003e\u003cstrong\u003eFluke TL175 – Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke TL175 TwistGuard™\u003c\/strong\u003e test leads offer adjustable exposed probe tips with a safety shroud, durable silicone insulation, and high safety ratings. Designed for field and bench applications, they include features to reduce tip exposure, indicate when insulation is damaged, and withstand heavy use—all without sacrificing flexibility or compatibility with standard 4 mm shrouded inputs.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTwistGuard™ adjustable tip-shroud (tip exposure from 19 mm down to 4 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWearGuard™ lead-wire indicator that shows insulation wear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSilicone leads: flexible in cold, durable in heat\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtra-heavy duty strain relief at probe and plug ends (tested for 30,000+ bends)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUniversal 4 mm shrouded banana plugs for wide compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClear safety markings showing correct CAT rating for the current tip exposure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: TL175\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRating: CAT II 1000 V \/ CAT III 1000 V \/ CAT IV 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Current: 10 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExposure Length (Probe Tip): 19 mm → 4 mm (0.75 in → 0.16 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation: Silicone, double insulated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Range: -20 … +55 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAltitude Rating: up to 2,000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePollution Degree: 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncluded: one pair (red \u0026amp; black) test leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical measurement tasks in industrial and field environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eServicing and calibration when tip exposure control is important\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse with multimeters, clamp meters, or other devices needing standard 4 mm banana leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironments requiring high durability and safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke TL175\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnhanced safety through adjustable exposure and tip guards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWear-indicator helps avoid using damaged leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust construction for long life under harsh conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh amperage and voltage ratings give flexibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke TL175 TwistGuard Test Leads are available now and ship worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50536282128662,"sku":"Fluke TL175","price":74.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-tl175-7409458.webp?v=1780276745"},{"product_id":"fluke-1777-three-phase-power-quality-analyzer","title":"Fluke 1777","description":"\u003ch2\u003e\u003cstrong\u003eFluke 1777 – Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 1777\u003c\/strong\u003e is a rugged, high-performance three-phase power quality analyzer designed to simplify diagnostics and long-term monitoring of electrical systems. It captures a wide range of power parameters, fast transients up to ±8 kV, detailed harmonic content to 30 kHz, and offers both live meter mode and long recording\/logging functionality. It's built for field-use, with solid safety ratings and versatile connectivity options.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThree-phase + neutral voltage and current inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCaptures high-speed transients up to ±8 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHarmonic analysis up to 30 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e24-bit synchronous sampling; automatic scaling for voltage \u0026amp; current sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports common power topologies (wye, delta, split phase, open delta, etc.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple log and record modes with large memory and micro-SD support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLive on-screen data: V, A, Hz, power, dips, swells, harmonics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePowerful analysis\/reporting via software for compliance (EN 50160, IEEE 519, IEC 61000 series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of Voltage Inputs: 4 (3 phases + neutral)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Rating: up to 1000 V rms \/ 1000 V DC (1700 V peak)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOvervoltage Rating: CAT III 1000 V \/ CAT IV 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHarmonic Bandwidth: DC to 30 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransient Capture Sampling Frequency: up to 20 MS\/s for fastest transients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard Sampling Rate (50\/60 Hz): ~80 kSamples\/s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: 24-bit synchronous sampling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Impedance (Voltage): ~10 MΩ (between phase-phase\/phase-neutral)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Inputs: automatic range depending on sensor (coil\/clamp etc), same bandwidth \u0026amp; resolution as voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMemory: internal + micro-SD card, supports multiple logging sessions (weeks) with event capture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply: Li-ion battery + mains + measurement circuit powering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -20 … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize \/ Weight: approx. 28.0 × 19.0 × 6.2 cm; ~2.1 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePower quality audits and harmonics evaluation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTroubleshooting voltage transients, dips, swells in industrial installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasuring and validating compliance with power quality standards (EN 50160, IEEE 519, etc.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong-term monitoring of power systems in utilities, manufacturing, or big infrastructure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 1777\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombination of very high transient capture plus wide harmonic bandwidth\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLive-meter and logging mode in one device gives flexibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong safety category lets you work at service entrance or downstream panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust memory, build quality, and analysis software simplify both testing and reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1777 Three-Phase Power Quality Analyzer is available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50536321122582,"sku":"Fluke 1777","price":26120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-1777-3820035.webp?v=1780276386"},{"product_id":"fluke-1630-2-fc-earth-ground-clamp","title":"Fluke 1630-2","description":"\u003ch2\u003e\u003cstrong\u003eFluke 1630-2 FC – Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 1630-2 FC\u003c\/strong\u003e is a stakeless earth ground clamp that enables accurate ground loop resistance and AC leakage current measurements without disconnecting ground systems or driving auxiliary stakes. Ideal for indoor, paved, or crowded areas, it includes a heavy-duty clamp jaw, large memory capacity, and rugged construction for job-site reliability. Wireless connectivity via Fluke Connect allows logging and review on mobile devices.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDual-jaw clamp for earth ground loop resistance without auxiliary stakes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC leakage current measurement without disconnecting ground stake\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge jaw opening (approx. 40 mm) to fit wide conductors or bus bars\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMemory logging: stores up to 32,760 readings at intervals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUser-defined high\/low alarm thresholds for quick pass\/fail evaluation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelectable band-pass filter to reduce noise in leakage current mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWireless sync via Fluke Connect for data sharing and cloud storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged build with jaw alignment and calibration stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: 1630-2 FC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Voltage to Earth Ground: 1,000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Range: 40 Hz to 1 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay Resolution: 9,999 counts; refresh rate 4 readings\/sec\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIngress Protection: IP30 (with jaw closed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Type: 4 × AA alkaline (IEC\/EN LR6)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: \u0026gt; 15 hours (ground resistance mode, backlight \u0026amp; RF off)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -20 … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Humidity: Non-condensing, ≤ 90% RH at lower temperatures, decreasing at higher temps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAltitude (Operating): up to 2,000 m; Storage altitude up to 12,000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJaw Opening \/ Conductor Size: approx. 40 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~ 880 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: ~ 283 × 105 × 48 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround Resistance Ranges \u0026amp; Accuracy:\u003cbr\u003e  - 0.025 … 0.249 Ω: ±(1.5 % + 0.02 Ω)\u003cbr\u003e  - 0.250 … 0.999 Ω: ±(1.5 % + 0.05 Ω)\u003cbr\u003e  - 1.000 … 9.999 Ω: ±(1.5 % + 0.10 Ω)\u003cbr\u003e  - 10.00 … 49.99 Ω: ±(1.5 % + 0.30 Ω)\u003cbr\u003e  - 50.00 … 99.99 Ω: ±(1.5 % + 0.50 Ω)\u003cbr\u003e  - 100.0 … 199.9 Ω: ±(3.0 % + 1.0 Ω)\u003cbr\u003e  - 200.0 … 399.9 Ω: ±(5.0 % + 5.0 Ω)\u003cbr\u003e  - 400 … 599 Ω: ±(10.0 % + 10 Ω)\u003cbr\u003e  - 600 … 1,500 Ω: ±(20.0 % + 10 Ω)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLeakage Current Range \u0026amp; Accuracy:\u003cbr\u003e  - 0.200 … 3.999 mA: 1 µA resolution, ±(2.0 % + 0.05 mA)\u003cbr\u003e  - 4.00 … 39.99 mA: 10 µA resolution, ±(2.0 % + 0.03 mA)\u003cbr\u003e  - 40.0 … 399.9 mA: 100 µA resolution, ±(2.0 % + 0.3 mA)\u003cbr\u003e  - 0.400 … 3.999 A: 1 mA resolution, ±(2.0 % + 3 mA)\u003cbr\u003e  - 4.00 … 39.99 A: 10 mA resolution, ±(2.0 % + 30 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTesting earth ground loop resistance in multi-grounded systems without disrupting connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasuring leakage current on earth conductors to identify fault or insulation issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround testing in structures where driving ground stakes is not possible (indoors, paved surfaces)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLogging ground and leakage data over time for maintenance and safety compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose Fluke 1630-2 FC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEliminates the need for auxiliary stakes or disconnection of ground systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge memory capacity simplifies data collection on site\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWireless connectivity allows easy sharing and remote monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust construction and reliable performance in tough environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1630-2 FC Earth Ground Loop \u0026amp; Leakage Clamp is available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50536326791446,"sku":"Fluke 1630-2","price":4180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-1630-2-6384390.webp?v=1780278137"},{"product_id":"fluke-1738-advanced-power-logger-three-phase","title":"Fluke 1738","description":"\u003ch2\u003e\u003cstrong\u003eFluke 1738 – Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 1738\u003c\/strong\u003e is a high-performance power quality logger designed for monitoring and diagnosing three-phase electrical systems. It includes four flexible current probes (for three phases + neutral), offers a vivid color touchscreen for field use, built-in logging of hundreds of parameters, and advanced event capture features such as waveform snap shots to catch power quality disturbances. Ideal for energy studies, power quality analysis, and long-term monitoring.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures all three phases plus neutral with four flexible current probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLogs extensive power quality parameters: voltage, current, harmonics, total harmonic distortion, active\/reactive\/apparent power, power factor, unbalance, etc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCaptures dips, swells, inrush currents, and provides waveform snapshots with timestamps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eColor touchscreen allows real-time viewing and operation in the field\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntelligent interface helps verify connections and reduce measurement error\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with Fluke Connect® and Energy Analyze Plus software for reporting and data analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple logging sessions stored onboard; review data before download\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan be powered directly from measured circuit; supports different voltage input options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 1738 Advanced Power Logger\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Measurement Range: up to 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Probe Options: iFlex probes of various ranges (e.g. 150 A, 300 A, 600 A, etc.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Types: Voltage, current, neutral, auxiliary inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHarmonic Measurement: 2nd through 50th harmonics for voltage and current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Range: ~42.5 Hz to 69 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSampling \u0026amp; Resolution: 16-bit synchronous sampling; high resolution RMS profiles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery: Li-Ion, replaceable, ~4 hours runtime in normal mode; extended in power-saving mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply Options: directly from circuit or standard power cord input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMemory: internal flash for many logging sessions, event storage, waveform data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: Color touch screen, graphical interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -20 … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity \u0026amp; Environmental: certified for industrial use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Category: High safety ratings (CAT IV \/ CAT III depending on configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLong-term monitoring of three-phase systems for energy use and cost tracking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower quality checks to identify harmonics, voltage dips, swells, inrush currents\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eValidation against standards (e.g. EN 50160) and utility compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial and utility panels, switchgears, motor loads, renewable generation setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 1738\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCombines flexible current probes with advanced logging making it very versatile\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge parameter set and event capture allow deep insight into power system health\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eColor touchscreen and guided setup reduce user error in field setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated reporting tools simplify analysis after measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong safety and build quality for demanding environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1738 Advanced Three-Phase Power Logger with current probes is available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50536333803798,"sku":"Fluke 1738","price":12710.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-1738-2976822.webp?v=1780277833"},{"product_id":"fluke-378-fc-clamp-meter","title":"Fluke 378 FC","description":"\u003ch2\u003e\u003cstrong\u003eFluke 378 FC – Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 378 FC\u003c\/strong\u003e is an advanced clamp meter with FieldSense™ technology that lets you measure AC voltage and current without making direct contact with live conductors. It also includes the flexible iFlex probe for larger conductors, offers True-RMS accuracy, and features a built-in Power Quality Indicator. Wireless Fluke Connect compatibility allows easy data logging and sharing.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFieldSense non-contact voltage and current measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures AC\/DC current through clamp up to 999.9 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eiFlex flexible current probe extends measurement range up to 2500 A AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS ensures accuracy on complex waveforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Quality Indicator identifies voltage, current, and power factor issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures AC\/DC voltage, mV, resistance, and capacitance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual display with backlight and HOLD function\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWireless connectivity with Fluke Connect for data transfer and logging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 378 FC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current (Clamp): up to 999.9 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current (iFlex): up to 2500 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current: up to 999.9 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC\/DC Voltage with Leads: up to 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage (FieldSense): up to 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC mV Range: up to 500 mV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: up to 60 kΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance: up to 1000 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eJaw Opening: 34 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible Probe Length: 1.8 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: Dual digital with backlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery: 2 × AA alkaline, approx. 200 hours life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: up to 90 % non-condensing at lower temperatures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Rating: CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFast current and voltage checks without direct contact to live conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial maintenance, utility inspections, and field troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnosing harmonics, inrush, or power factor problems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasuring current on large conductors where flexibility is needed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose Fluke 378 FC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSafer, faster testing with FieldSense non-contact technology\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtended current range with iFlex for large conductors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS accuracy for real-world distorted signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated Power Quality Indicator to detect problems early\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 378 FC True-RMS Clamp Meter is in stock and ships worldwide.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50536394391830,"sku":"Fluke 378 FC","price":1420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-378-fc-8447118.webp?v=1780277109"},{"product_id":"fluke-77-iv-wide-range-digital-multimeter","title":"Fluke 77 IV","description":"\u003ch2\u003e\u003cstrong\u003eFluke 77 IV – Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 77 IV\u003c\/strong\u003e is a rugged field-grade multimeter built to handle a wide range of electrical and electronic diagnostic tasks. It covers high voltages (up to 1000 V), both AC and DC, measures current up to 10 A, includes capacitance and frequency measurement, plus standard resistance, continuity and diode testing. It meets high safety standards and is ideal for field service or bench work.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures DC and AC voltages up to 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC\/AC current measurements up to 10 A (continuous)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency and capacitance measurement functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge backlit display with 6000-count resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMin \/ Max recording of signal fluctuations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto and manual ranging modes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety category ratings: CAT III 1000 V \/ CAT IV 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDurable over-molded case with built-in probe holders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: Fluke 77 IV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Range: 6.000 V to 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Voltage Accuracy: ±(0.3% + 1 count)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Range (Average Responding): 600.0 mV to 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Voltage Accuracy: ±(2.0% + 2 counts) for 45-1000 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current Range: 60.00 mA to 10.00 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current Accuracy: ±(1.5% + 2 counts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Range: 60.00 mA to 10.00 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current Accuracy: ±(2.5% + 2 counts) for 45-1000 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Range: 600.0 Ω to 50.00 MΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance Accuracy: ±(0.5% + 1 count)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Range: 1 nF to 9,999 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance Accuracy: ±(1.2% + 2 counts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Range: 99.99 Hz to 99.99 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Accuracy: ±(0.1% + 1 count)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: 6000 counts; bar graph with 33 segments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSurge Protection: 8 kV peak per IEC 61010\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFuse Protection: 440 mA fuse (mA input), 11 A fuse (A input), both fast-acting, 1000 V rated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAltitude: Operating up to 2,000 m; storage up to 12,000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Type: 9 V alkaline; typical battery life ~400 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTroubleshooting in field service for windows, HVAC, electrical panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBench work for basic electronics maintenance and repair\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement of voltage, current, resistance, and frequency in industrial and commercial settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironments where high safety category is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose the Fluke 77 IV\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHigh voltage \u0026amp; current range with strong safety certifications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCombines needed measurement functions in one durable tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong battery life and robust display make it dependable in harsh field conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFluke 77 IV Digital Multimeter is in stock and available. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50536399831318,"sku":"Fluke 77 IV","price":830.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-77-iv-1768487.webp?v=1780276464"},{"product_id":"fluke-561-hvac-infrared-contact-thermometer","title":"Fluke 561","description":"\u003ch2\u003e\u003cstrong\u003eFluke 561 – Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 561\u003c\/strong\u003e combines non-contact infrared temperature measurement with contact measurement using Type K thermocouples. It enables technicians to measure both from a distance (IR) and directly via thermocouple probes, making it ideal for HVAC, electrical, industrial maintenance, refrigeration work, and situations where safety and access are important. It comes with a Velcro pipe probe for superheat \/ sub-cooling, a laser pointer for aiming, and has selectable emissivity for shiny or reflective surfaces.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDual mode: infrared (non-contact) plus Type K contact thermocouple input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures superheat and sub-cooling with included Velcro pipe probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSingle-point laser sighting for targeting IR measurement spot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable emissivity with three settings (low, medium, high) for accuracy on different surfaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMIN \/ MAX \/ DIF functions for identifying temperature extremes and differences\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay hold \u0026amp; backlit LCD with dual readout (current \u0026amp; Max\/Min\/Dif\/K-TC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight and portable (~340 grams)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperates on 2 AA batteries with approx. 12-hour battery life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Range: −40 °C to +550 °C (−40 °F to +1022 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay Resolution: 0.1 °C \/ 0.1 °F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistance-to-Spot Ratio (D:S): 12:1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmissivity Settings: low (0.30), medium (0.70), high (0.95)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay Accuracy: ±1.0 % of reading ±1° (°C\/°F), whichever is greater; below 0 °C \/ 32 °F includes additional ±0.1°\/°F per degree below\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResponse Time: 500 ms (95 % of reading)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpectral Response: 8-14 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLaser Sighting: Single-point laser; turns off above ambient temperature of approx. 40 °C (104 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 10-90 % RH non-condensing (at \u0026lt; 30 °C \/ 86 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay Hold Time: 7 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBacklight: Yes (LCD with dual temperatures + mode indicator)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 … +50 °C (32 … 120 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -20 … +65 °C (-25 … +150 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower: 2 × AA batteries (alkaline or NiCD)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Life: Approx. 12 hours of active use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC\/R diagnostics (superheat, sub-cooling, duct \/ pipe temperature)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical maintenance (checking hot spots, connections, insulation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial \u0026amp; manufacturing processes needing both IR scanning and probe measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSituations where measuring unreachable or energized surfaces safely matters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose Fluke 561\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOffers IR and contact thermometry in one tool, reducing need to carry separate instruments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable emissivity helps improve accuracy on different surface types\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePipe probe included, which adds versatility for HVAC and piping work\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong durability, user-friendly display, and built-in functions to simplify problem detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 561 HVAC Infrared \u0026amp; Contact Thermometer is available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50536406647062,"sku":"Fluke 561","price":562.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-561-2123869.webp?v=1780277236"},{"product_id":"fluke-1775-three-phase-power-quality-analyzer","title":"Fluke 1775","description":"\u003ch2\u003e\u003cstrong\u003eFluke 1775 – Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 1775\u003c\/strong\u003e is a high-precision power quality analyzer designed for three-phase electrical systems. It delivers advanced logging of power, voltage, current, harmonics, and power quality events. With excellent transient capture and wide bandwidth, it helps identify problems like spikes, dips, swells, and harmonic distortion before they damage equipment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFull three-phase + neutral measurement capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh transient capture up to ±8 kV for detecting damaging voltage spikes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide PQ measurement bandwidth from DC to 30 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e24-bit synchronous sampling with high resolution and accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with flexible current probes for extended current ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eColor touchscreen for intuitive field operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes automatic capture of 500+ PQ parameters, dips\/swells, harmonics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports USB, Ethernet, WiFi\/Bluetooth for data\/log transfers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 1775\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Input (rms): up to 1000 V AC\/DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBandwidth for PQ measurements (excluding transients): DC to 30 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransient Sampling Rate: 1 MS\/s for high-frequency pulse capture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: 24-bit synchronous sampling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Input Ranges (with probes or clamps):\u003cbr\u003e - iFlex probes: up to ~1500 A to 6000 A depending on probe type\u003cbr\u003e - Clamp sensors: lower ranges down to tens of amperes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Rating: CAT IV 600 V \/ CAT III 1000 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Impedance (voltage): ~10 MΩ between phase-to-phase or phase-to-neutral\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of Logged Parameters: over 500 by default\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage \/ Memory: large internal memory for logging long-term power quality events\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: Color touchscreen interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSize \/ Weight: approx. 28 × 19 × 6.2 cm; ~2.1 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePower quality audits in industrial and commercial sites\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring and diagnosing harmonics, transients, and waveform distortion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInvestigating power disturbances, dips, swells, and energy irregularities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUtility compliance (standards like EN 50160, IEEE 519) and preventive maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose Fluke 1775\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eExcellent transient resolution helps catch harmful spikes before damage occurs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide bandwidth and high resolution support accurate harmonic analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible current probe options allow measuring large conductors and different scenarios\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust safety ratings make it safe for use at service entrances or high voltage panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModern interface and connectivity simplify data logging and reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1775 Three-Phase Power Quality Analyzer is available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50536660402454,"sku":"Fluke 1775","price":18160.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-1775-6119082.webp?v=1780276817"},{"product_id":"fluke-902-fc-hvac-clamp-meter","title":"Fluke 902 FC","description":"\u003ch2\u003e\u003cstrong\u003eFluke 902 FC – Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFluke 902 FC\u003c\/strong\u003e is a versatile clamp meter designed for HVAC\/R technicians. It offers True-RMS measurements for both AC voltage and current, microamp DC for flame sensors, and additional functions like temperature, capacitance, and resistance. It pairs with Fluke Connect for wireless data logging, enabling safer and more efficient work in panels or tight spaces.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS AC\/DC voltage up to 600 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC current (clamp) up to 600 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC current measurement down to microamps (≈ 200 µA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance up to 60 kΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance measurement up to 1,000 µF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContact temperature mode (-40 … +400 °C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge backlit display with Min\/Max recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWireless connectivity with Fluke Connect for remote reading and logging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel: Fluke 902 FC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC Current (Clamp): Range up to 600 A; accuracy ~2.0% ±5 digits (45-65 Hz); 2.5% ±5 digits (65-400 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC\/DC Voltage: Range up to 600 V; resolution 0.1 V; accuracy ~1.5% ±5 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance: Up to 60 kΩ; resolutions 0.1 \/ 1 \/ 10 Ω; accuracy ~1% ±5 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitance: Ranges 100 µF \/ 1,000 µF; accuracy ~1% ±4 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC Current: ~200 µA max range; resolution ~0.1 µA; accuracy ~1% ±5 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContact Temperature: Range -40 … +400 °C; resolution 0.1°; accuracy ~1% ±8 digits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuity Beeper: threshold ≤ 30 Ω; beeper volume ~75 dBA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplay: Backlit, with comfortable readability in low light\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery: 2 × AA alkaline\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -10 … +50 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40 … +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Ratings: CAT III 600 V \/ CAT IV 300 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: ~230 × 83.7 × 45.4 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: ~419 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC\/R system maintenance (pilot lights, flame sensor, blower motors)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChecking high current draws in motors or compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasuring voltages and resistances safely in panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLogging readings via smartphone app while staying at safe distance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Choose Fluke 902 FC\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOffers both clamp measurements and microamp ranges for specialized HVAC tasks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong safety ratings make it suitable for hazardous measurement environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWireless features reduce the need for PPE and improve efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrue-RMS ensures accurate readings on non-linear loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOrder Now\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 902 FC True-RMS HVAC Clamp Meter is available for purchase. Ships worldwide.\u003c\/p\u003e\n\u003chr\u003e\n\u003cpre\u003e\u003ccode\u003e\n\u003c\/code\u003e\u003c\/pre\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":50536691433750,"sku":"Fluke 902 FC","price":646.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/files\/fluke-902-fc-6235231.webp?v=1780276692"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/1049\/2438\/collections\/fluke-2061602.webp?v=1780250347","url":"https:\/\/ddpartssolution.com\/collections\/fluke-test-measurement-equipment.oembed?page=5","provider":"DDPARTS SOLUTION","version":"1.0","type":"link"}